6 720 608 542
4
Appliance details
FCC:
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2)
this device must accept any interference received,
including interference that may cause undesired
operation.
Fig. 1
2 Appliance details
2.1 Features
Parts
• Key Pad interface control
• High power pre-mix compact burner with low NOx
emissions
• Modulating Gas Valve with constant gas:air ratio
control
• Modulating water valve for improved comfort and
temperature control.
High quality materials for long working life
• Copper heat exchanger
• High efficiency Ceramat Burner
• Compact space saver: mounts on a wall with a
supplied bracket.
Features
• Real-time diagnostics for troubleshooting/informational
purposes
• LCD Display with backlight
• On/Off and Temperature control switches
• Reset button
• Program button (Selectable temperature default)
• Failure codes for easy diagnostics and repair
• Easily removable one-piece cover
• Built in freeze prevention.
Note: The freeze prevention is designed to provide
protection for the water heater down to approximately 5°F
for short term conditions only. It will not protect the
appliance in areas where the temperature is routinely
expected to be below freezing.
- The freeze prevention will not protect plumbing outside
the appliance from freezing. Precautions should be taken.
Accessories (Bosch part #)
• Optional wireless remote control accessory to operate
with the appliance (TSTAT2)
• Cascading kit (TLINK)
• Outdoor kit (AQOK)
• Gas conversion kit (8719002176)
• Vertical vent kit (ESVVT)
• Horizontal vent kit (AQ3ES
1)
)
• Stainless steel bird screen (L2594)
(fits into a 3” PCV fitting - Intake vent).
Warning: The anti freeze kit is
designed to provide protection for the
water heater down to approximately 5°F
for short term conditions only. It will not
protect the appliance in areas where the
temperature is routinely expected to be
below freezing.
B The anti freeze kit will not protect
plumbing outside the appliance from
freezing. Precautions should be taken.
B Always drain the water heater if it will be
exposed to long term freezing
conditions. See Section 6.2 Winterizing
for seasonal use.
Warning: If a relief valve discharges
periodically, this may be due to thermal
expansion in a closed water supply
system. Contact the water supplier or
local plumbing inspector on how to
correct this situation. Do not plug the
relief valve.