Installation instructions
3.3.1 Vent material and specifications
Establish vent clearances that comply with the vent
manufacturer's specifications. In all cases, follow local
codes. See Table 2.
The appliance should be located as close to the point
of vent termination as possible. The maximum vent
length is 26 feet (8 m) with one 90 degree elbow and
approved terminator. Subtract 2.5 feet from the total
vent length for each additional 90° elbow used (a
maximum of three 90° elbows are permitted in the
total equivalent vent length calculation, see
section 3.3.4), or subtract 1.25 feet for every 45° elbow
used. Horizontal sections of vent must pitch upwards
towards termination ¼" for every foot of horizontal
length, to prevent the pooling of condensate, and be
supported at 4 foot intervals with overhead hangers.
Exception: horizontal run between last elbow
and termination must pitch down to termination
1/4" per foot.
Note: For horizontal terminations, venting must
terminate once it penetrates to the outside of the
structure. There must be no sections of vent pipe
exposed to the outdoors other than the
termination.
Note: Listed thimbles or collars are necessary where
venting passes through wall and ceiling partitions. If the
vent system passes through combustible areas where
the vent clearance requirements cannot be maintained,
it is permissible to chase straight sections of sealed 3
inch single wall vent through 4 inch (or greater) Type-B
vent. The distance to combustibles using this chase
technique is 1 inch
1)
. Note: Type-B vent must never
be used as the actual exhaust vent system for the
appliance, as it is not gas tight and illegal for use
with this appliance. This will create a serious
health hazard and void the warranty.
For specific questions concerning vent material,
specifications, usage or installation, please contact the
vent manufacturer directly.
Minimum exhaust vent length
( > 3 feet of straight pipe)
Fig. 8 (combustion air piping not shown)
Diam. Min.
lenght
Max.
length
Material
Exhaust
Vent
3 or 4
inches
3 feet 26 feet with
1 90° elbow
and terminal
Sealed single wall
stainless steel
(AL29-4C)
Intake
Vent
3 or 4
inches
1 90°
elbow
26 feet with
1 90°elbow
and terminal
Sealed PVC or
any other rigid or
semi rigid pipe
Table 2 Venting Specifications
1) in all cases, follow local codes.
3”
VENTING
Z flex Protech Heat Fab
3”
Horizontal
Terminal
2SVSTB03 FSTB3 9390 TEE
3” Vertical
terminator
2SVSRCF03 FSRC3 5300CI
Table 3 Terminator Part Numbers
Fittings or Piping Equivalent
feet m
45 degree elbow 1.25 0.38
90 degree elbow 2.5 0.76
pipe per foot 1 0.30
Table 4 Friction Loss Equivalent in piping and fittings
Company Contact info
Z-flex www.z-flex.com
800-654-5600
ProTech Industries www.protechinfo.com
800-766-3473
Heat-Fab www.heatfab.com
800-772-0739
Table 5 Vent manufacturers