3.1 Tools required for installation
Philips head screwdriver
Flat head screwdriver
Adjustable wrench
Level
Thermometer
Standard plumbing tools
Manometer
Drill
Pipe wrench
Adjustable pliers
Pipe fitting tools
Hacksaw
Hole saw.
3.2 Introduction
Please follow these instructions. Failure to follow
instructions may result in:
B Damage or injury.
B Improper operation.
B Loss of warranty.
If you are unable to perform the tasks required to install
this heater properly, please contact a locally licensed
plumber or gas technician.
3.3 Venting
i
Common installation practice is to
first determine the venting/combus-
tion air point of termination, then de-
sign the piping layout back to the
heater.
Warning: Do not reduce the vent
(exhaust and combustion) pipe sizes
and do not common vent with any other
vented appliance or stove.
Warning: Failure to vent the exhaust
gases to the outside with sealed
stainless steel vent pipe (AL29-4C)
may result in dangerous flue gases
filling the structure in which it is
installed.
Warning: Do not mix vent pipe or
joining methods from different
manufacturers.
Warning: Proper end terminal / rain
cap must be used. Failure to do so may
result in damage to the appliance.
This damage is not covered under
the manufacturer's warranty.
Caution: The vent system must be
installed by a qualified installer in
accordance with these instructions. If
improperly installed, a hazardous
condition such as explosion or carbon
monoxide poisoning could result.
Bosch Water Heating will not be
responsible for improperly installed
appliances.
Warning: In areas where outside
temperatures routinely come close to
freezing, sealed combustion operation
is required. Use separate terminations
for combustion and vent, which must be
installed on the same wall or roof
surface, however never facing the
direction of prevailing winds. Failure to
do so may result in heat exchanger
freezing up and bursting. This failure is
not covered under the manufacturer's
warranty.