EasyManua.ls Logo

Bosch GWI-N Series - User Manual

Bosch GWI-N Series
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Page 1 from 76 6 720 814 719 SM FP_Australia 2017/04 EN
INSTANTANEOUS GAS WATER HEATER
GWI-N
FAN PRESSURIZED GAS WATER HEATER FOR
INDOOR AND OUTDOOR INSTALLATION
TRAINING AND SERVICE INFORMATION FOR AFTER SALES
This document is restricted to exclusive use by the official service partners. Each
country should adapt the manual and its contents to the available range.
12 / 16 / 20
12
16 / 20 / 26

Questions and Answers

  • A
    Amanda BrewerSep 23, 2025
    What happens if there is a failure in the heat exchanger outlet NTC of my Bosch GWI-N?
    • W
      Wendy EdwardsSep 23, 2025
      A warning will appear on your Bosch Water Heater. This will self reset when conditions are corrected. Note: this error only exists in outdoor GWH16/20/26 models.
  • C
    charleslorraineAug 23, 2025
    Why is there insufficient air flow at start up in my Bosch GWI-N?
    • M
      michael65Aug 23, 2025
      If the Bosch Water Heater detects insufficient airflow at start up and you have Software Version AF1112, the burner will lockout or shutdown, but it will self-reset when you close the water. If you have Software Version AF1113, the burner will lockout or shutdown, and you'll need to manually reset it.
  • S
    Stephanie BakerAug 25, 2025
    What to do if the fan is unplugged in my Bosch Water Heater?
    • B
      bennettjenniferAug 25, 2025
      If the fan is unplugged or there is no detection of rotation/speed signal from the fan in your Bosch Water Heater, a lockout will occur. To reset, close the water.
  • L
    Laura SwansonAug 27, 2025
    What happens if my Bosch Water Heater gets too hot?
    • J
      Jessica StoutAug 27, 2025
      If the hot water outlet sensor detects an over-temperature (T > 85ºC) in your Bosch Water Heater, a warning lockout will occur. The system will self-reset when the temperature drops below 60ºC.
  • H
    Holly CannonAug 27, 2025
    Why does my Bosch Water Heater show a water flow signal over the maximum value?
    • K
      Kimberly LandryAug 27, 2025
      If the water flow signal exceeds the specified maximum value (flow > 25 l/min) in your Bosch Water Heater, a warning will be issued. This will self-reset by reducing the water flow.
  • T
    tschneiderSep 17, 2025
    What does it mean if the bypass valve is damaged on my Bosch Water Heater?
    • M
      Michael LeachSep 18, 2025
      If the bypass valve is damaged or disconnected in your Bosch Water Heater, a warning will be issued only if the bypass valve is activated. Note that this error only exists in outdoor GWH16/20/26 models.
  • L
    Levi JacksonSep 14, 2025
    What happens if the modulating solenoid is disconnected in my Bosch GWI-N?
    • H
      Holly MataSep 14, 2025
      If the modulating solenoid is disconnected in your Bosch Water Heater, the system will self-reset when the issue is resolved.
  • V
    vriceSep 15, 2025
    What to do if my Bosch GWI-N Water Heater detects high temperature inside the box?
    • T
      Tracy TuckerSep 15, 2025
      If a high temperature is detected by the NTC inside the box (T box > 70ºC) in your Bosch Water Heater, a warning will be issued. Reset the system by closing the water.
  • A
    anthonybowmanSep 6, 2025
    What does it mean if both inlet and outlet NTC temperature sensors are damaged on my Bosch GWI-N Water Heater?
    • H
      hmooreSep 6, 2025
      If both the inlet and outlet NTC temperature sensors are damaged (open/short circuit) in your Bosch Water Heater, a lockout will occur, requiring a manual reset.
  • A
    Amy GrantSep 3, 2025
    What happens if the Air Box NTC temperature sensor is defected in my Bosch GWI-N?
    • J
      John BeasleySep 3, 2025
      If the Air Box NTC temperature sensor in your Bosch Water Heater is defected (open or short circuit), a lockout will occur. This will self-reset when the conditions are corrected.

Bosch GWI-N Series Specifications

General IconGeneral
ModelGWI-N Series
Power SupplyElectric
PhaseSingle
TypeTankless
Temperature Range30-55°C

Related product manuals