EasyManua.ls Logo

Bosch HBL5551UC - Displaying Error Memory; Testing Relays; Testing Front Panel

Bosch HBL5551UC
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
58300000202181 ARA EN B November 2018 Service Manual for Bosch 500 Series Built-in Wall Ovens
Page 33 of 41
Copyright by BSH Home Appliances Corporation 1901 Main St Suite 600 Irvine, CA 92614 800 944-2904
This material is intended for the sole use of BSH authorized persons and may contain conf idential and proprietary inf ormation. Any unauthorized rev iew, use, copying, disclosure, or distribution in any format is prohibited.
Model(s)
Option Code
HBL5351UC
1053
HBL5451UC
HBN5451UC
HBL57M52UCC
3053
HBL5551UC
1153
HBL5651UC
HBN5651UC
3153
1. Follow the steps in the Accessing Service Mode sections.
2. Advance through the menu until OC: #### is visible
(#### = current option code).
3. Press (+) or (-) to enter editing mode; option code will blink
when editable.
4. Press (+) or (-) to cycle through the available option codes for
the 500 series ovens.
5. Press Clock when the correct option code is displayed; the
code will be saved when exiting Service mode.
Always confirm that the oven and all components are functioning
normally after setting the option code.
7.2.4 Displaying Error Memory
1. Follow the steps in the Accessing Service Mode sections.
2. Advance through the menu until Er: is visible
3. Press (+) or (-) to access the error memory.
If no errors are logged, nonE will be visible.
Errors are displayed in numeric order; the error code (Exxx)
will appear on the left and the error count will appear on the
right of the display. (Example: E206: 003 indicates that error
code 0206 has been logged three times.)
4. Press (+) or (-) to cycle through the error memory.
5. Press Clock to return to the menu screen.
7.2.5 Testing Relays
Refer to the tables in the Accessing Service Mode section for a list of
relay test menu codes.
1. Follow the steps in the Accessing Service Mode sections.
2. Advance through the menu until the desired relay test is
visible; Rx: will appear in the display.
The initial displayed state will reflect the current state of the
relay. (Example: R1: 2 should be in the initial display when
selecting the Door Lock Relay Test, indicating the relay is
closed.)
3. Press (+) or (-) to change the state of the relay.
4. Press Clock to return to the menu screen.
7.2.6 Testing Front Panel
The Front Panel Test will confirm that all control inputs are connected
and operating. Both encoder switches and the touch control module
(TCM) are tested.
1. Follow the steps in the Accessing Service Mode sections.
2. Advance through the menu until FP: appears in the display.
3. Press each key and rotate each knob at least one detent.
When a key is pressed, its identifier will be displayed to the left
of the colon and total input count will be displayed to the right;
encoder switches are identified as S1 (mode) and S2 (temp).
4. When all inputs are detected, the control will reset and enter
normal operating mode.
To exit the test, it must either be successfully completed or the
power must be reset.
Table 12 Option codes for 500 series wall ovens