Service Manual for Bosch Built-in Wall Ovens
Figures 16 Relay locations on the double oven control module
After installing a new user interface board, always reset the oven and
test.
4.9 PC Control Module (Relay Board)
To access the PC control module, pull the unit out from the wall 15-16
inches, and remove the access panel (3 T20 screws) on the top of the
unit. See Figure 14.
Figure 14 PC Control Module is visible after removing access panel.
Whenever possible, conduct troubleshooting tests at the control
module. Refer to Figures 15 -16 for plug and relay locations.
NOTICE
More than 75% of the control modules returned to the factory are fully
functional. Before diagnosing a bad control module, be sure to
disconnect and reconnect each wire/wire harness.
Figure 15 Plug locations on the double oven control module
X101
X102 X107
X103
X104
X105 X106
X1
X2
X3
X209
X210
X110
X204
Rear
Front
X202
X201
X207
X206
X203 X205
Page 15 of 36