58300000202181 ARA EN B November 2018 Service Manual for Bosch 500 Series Built-in Wall Ovens
Page 30 of 41
Copyright by BSH Home Appliances Corporation 1901 Main St ▪ Suite 600 ▪ Irvine, CA 92614 800 944-2904
This material is intended for the sole use of BSH authorized persons and may contain conf idential and proprietary inf ormation. Any unauthorized rev iew, use, copying, disclosure, or distribution in any format is prohibited.
Cavity 1 / Cavity 2 meat probe
error
“Hot” wire shorted to ground. Connection to
the probe changes from connected-to-
disconnected multiple times. Probe is disabled,
but oven continues to operate. Error will be
cleared and probe enabled after a control
reset. Standard probe assembly is part of the
control module; see Communication Schematic
Check wires and connections; connector
may be loose and shorted to cavity or other
dead metal.
Check for dirty contact within probe
receptacle.
Cavity 1 / Cavity 2 meat probe
sensor temperature too high
Measured temperature of probe is higher than
allowable limit. Oven will stop heating until
probe is removed.
Check with customer to determine if probe
was in receptacle and not in food.
Check probe operation and resistance.
Check for loose connections and/or pinched
wires.
Cavity 1 / Cavity 2 meat probe
sensor temperature too low
Measured temperature of probe is lower than
allowable limit. Oven will stop heating until
probe is removed.
Check with customer to determine if probe
was used in frozen food.
Check probe operation and resistance.
Check for loose connections and/or pinched
wires.
Cavity 1 / Cavity 2 door latch error
Switch signals lost by latch position switch.
If a locked or unlocked signal error occurs, all
heating elements will be disabled. Error may
be cleared only by a software reset. See Cavity
1 (upper) Small Load Schematic.
Check switch connections.
Check wires between connector and control
module.
Check switch operation.
Electronics Delta temperature too
high
Temperature sensor on the control module
detects temperature changes that, over time,
are higher than limit value. Control turns off
heating elements and fan defaults to high
speed. When cavity temperature reaches
212°F/100°C, heating will resume and error
will be cleared. (If self-clean was running, it will
be disabled until a control reset is performed.)
Check connections to cooling fan and to
control module (see Small Load Schematic).
Check element operation.
Check for air obstruction or damaged
upper/lower ventilation trims.
Check for stuck relays.