EasyManua.ls Logo

Bosch HDD80051UC - Install Electrical Wiring; Remote Blower Wiring; Flex Blower Wiring

Bosch HDD80051UC
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English 20
INSTALLATION
Install electrical wiring
CAUTION: Installation work and electrical wiring must
be done by quali ed person(s) in accordance with all
applicable codes and standards, including re-rated
construction.
CAUTION: Do not use an extension cord. If the
product power cord is too short, have a quali ed
electrician install a three slot receptacle.
1. Install a standard wiring box, with 3-pronged receptacle,
within reach of the downdraft’s power cord.
2. Remove electrical panel wiring box cover. Secure
blower power cable to electrical panel wiring box with
U.L. approved strain relief.
Based on blower selected, go to the relevent
section:
A - Flex blower wiring
B - Remote blower wiring
A - Flex blower wiring
3. Connect exible blower wires to wires in electrical panel
wiring box as shown. Cap off BLUE wire (LOW 1).
4. Replace wiring box cover.
From exterior or
in-line blower
FLEXIBLE
BLOWER
M
ELECTRICAL PANEL
WIRING
BOX
BROWN (HIGH 4)
WHITE (NEUTRAL)
RED (MED 2)
GROUND SCREW
ORANGE (MED-HIGH 3)
BLACK
WHITE
BLUE (cap off)
RED
ORANGE
GREEN
B - Remote blower wiring
3. The following exterior or inline blowers can be used:
DHG6023RUC - 600 cfm (17 m
3
/min) Remote Blower
DHG6015NUC - 600 cfm (17 m
3
/min) Inline Blower
120 VAC  60 Hz  5.0 A (max.)
NOTE: Some blowers may come with plugs or connectors.
These should be removed and the 14/4 ROMEX or Conduit
wiring should be connected in and approved junction box.
As an alternative, the BSH 25-ft. Extension Cable Kit
(EXTNCB25W) and the Extension Cable Connection Kit
(EXTNSET4) can be used in place of the ROMEX or conduit
wiring. Please follow all required and recommended wiring
instructions in this manual and the extension cable kits.
4. Connect power wires to wires in electrical panel wiring
box as shown.
5. Replace wiring box cover.
REMOTE
BLOWER
M
ELECTRICAL PANEL
WIRING
BOX
BROWN (HIGH 4)
WHITE (NEUTRAL)
RED (MED 2)
GROUND SCREW
ORANGE (MED-HIGH 3)
14/4 ROMEX
OR CONDUIT
All manuals and user guides at all-guides.com

Table of Contents

Other manuals for Bosch HDD80051UC

Related product manuals