enSet up and connect
In standby mode, the brightness of
the control panel is reduced and the
light bar is lit.
As soon as you operate the display
or open the door, the standby mode
is deactivated.
You can turn off the light bar for
standby mode.
4.2 Site Criteria
WARNING
Danger of explosion!
If the unit is in too small a room, a
leak in the refrigeration cycle could
result in a flammable mixture of gas
and air.
▶ Only set up the device in a room
with a volume of at least 1 m3per 8
g of refrigerant. The amount of
refrigerant is on the type plate.
→
fig
/
Turn on the light bar
▶ + Hold down for 3 seconds until
you hear an audible signal.
Turn off the light bar
▶ + Hold down for 3 seconds until
you hear an audible signal.
1
6
Depending on the model, the weight of
the device can be up to 120 kg ex
works.
The ground must be sufficiently
stable to support the weight of the
device.
4 set up and
Connect
4.1 Scope of Delivery
Permissible room temperature
The permissible room temperature
depends on the climate class of the
device. The climate class is on the
rating plate. →
fig
After unpacking, check all parts for
transport damage and that the
delivery is complete.
If you have any complaints, contact
your dealer or our customer service
→
page 30
.
1
/
6
climate class
see
Permissible room temperature
temperature
The delivery consists of: ¡
standing device
¡equipment and accessories1
¡assembly Instructions
¡Instructions for use
¡Customer Service Directory
¡warranty insert2
¡energy label
¡Information on energy consumption
and noises
SN
N
ST
T
10°C…32°C
16°C…32°C
16°C…38°C
16°C…43°C
The device is fully functional within the
permissible room temperature.
If you operate a device in climate
class SN at colder room
temperatures, damage may occur
1
Depending on device
equipment Not in all countries
2
14