DINION inteox 7100i IR | FLEXIDOME inteox 7100i Configuration | en 31
Bosch Security Systems B.V.
User manual
2021-08 | V01 | DOC
Settings for selected recordings
Recording includes
Select what is to be included in the recordings:
Audio: If audio is not enabled, Off is shown. Click on Off and the page is redirected to
the Audio section.
Metadata.
You can specify whether, in addition to video data, audio data and metadata (for example
alarms, VCA data and serial data) should also be recorded. Including metadata could make
subsequent searches of recordings easier but it requires additional storage capacity.
!
Caution!
Without metadata, it is not possible to include video content analytics in recordings.
Select the mode for standard recordings:
Continuous: the recording proceeds continuously. If the maximum recording capacity is
reached, older recordings are overwritten automatically.
Pre-alarm: recording takes place in the pre-alarm time, during the alarm and during the
post-alarm time only.
Off: no automatic recording takes place.
Stream
Select the stream to be used for standard recordings:
Stream 1
Stream 2
I-frames only
Alarm recording
Select a period for the Pre-alarm time from the list box. The RAM option allows the pre-alarm
recording ring buffer to be stored in RAM as long as it fits, depending on bit rate settings. This
avoids writing to the SD card or iSCSI. The pre alarm ring is written to storage only on alarm.
Select a period for the Post-alarm time from the list box.
Alarm stream
Select the stream to be used for alarm recordings:
Stream 1
Stream 2
I-frames only
Check the encoding interval and bit rates from profile: box and select an encoder profile to
set the associated encoding interval for alarm recording.
Export to account
To send standard H.264 or H.265 files to the target address, select an account and check
Export from memory.
If the target has not yet been defined, click Configure accounts to jump to the Accounts page
where the server information can be entered.
Alarm triggers
Select the alarm type that is to trigger an alarm recording:
Alarm input
Analysis alarm
Select the Virtual alarm sensors that are to trigger a recording, via RCP+ commands or alarm
scripts, for example.