T
Tyrone MooreAug 11, 2025
What to do if the camera operates, but there is no data link on a Bosch NPD-6001A?
- KKristina VasquezAug 11, 2025
If your Bosch Switch-connected camera operates but there's no data link, first, ensure the port indicator on the front panel is continuously lit. If you're using an external power splitter, try replacing it with one that is known to work. Also, confirm that you're using standard UTP/FTP Category 5 straight (non-crossover) cabling with all four pairs for this link and that the Ethernet cable length is less than 100 meters from the Ethernet source to the camera. Finally, try reconnecting the camera to a different midspan, as a faulty port or RJ45 connection on the midspan could be the issue.