ID Gas Nz Qn (kW) m
3
/h g/h Bp M
G20/25mbar 91 1,75 0,167 - 32 B
G25/20mbar 100 1,75 0,194 - 32 B
G25/25mbar 95 1,75 0,194 - 32 B
G25.1/25mbar 95 1,60 0,177 - 32 B
G25.3/25mbar 95 1,75 0,19 - 32 B
G30/29mbar 66 1,75 - 127 32 A
G30/37mbar 61 1,75 - 127 32 A
G30/50mbar 58 1,75 - 127 29 A
G31/37mbar 66 1,75 - 125 32 A
G20/20mbar 128 3,00 0,286 - 39 B
G20/25mbar 120 3,00 0,286 - 39 B
G25/20mbar 134 3,00 0,333 - 39 B
G25/25mbar 126 3,00 0,333 - 39 B
G25.1/25mbar 126 2,80 0,31 - 39 B
G25.3/25mbar 126 3,00 0,325 - 39 B
G30/29mbar 87 3,00 - 218 39 A
G30/37mbar 80 3,00 - 218 39 A
G30/50mbar 75 3,00 - 218 35 A
G31/37mbar 87 3,00 - 214 39 A
G20/20mbar 138 3,50 0,334 - 61 B
G20/25mbar 130 3,50 0,334 - 61 B
G25/20mbar 143 3,50 0,388 - 61 B
G25/25mbar 136 3,50 0,388 - 61 B
G25.1/25mbar 136 3,30 0,365 - 61 B
G25.3/25mbar 136 3,50 0,379 - 61 B
G30/29mbar 90 3,30 - 240 61 A
G30/37mbar 84 3,30 - 240 61 A
G30/50mbar 71 3,30 - 240 55 A
G31/37mbar 90 3,30 - 240 61 A
17
en
Safe installation
Follow these safety instructions when installing the
appliance.
¡ Read this instruction manual carefully.
¡ The images shown in these instructions are for
guidance only.
¡ The appliance can only be used safely if it is cor-
rectly installed according to the safety instructions.
The installer is responsible for ensuring that the
appliance works perfectly at its installation loca-
tion.
WARNING‒Risk of explosion!
Escaping gas may cause an explosion.
▶ All Installation, connection, regulating and conver-
sion work to a different gas type must be carried
out by an authorised professional while taking into
account the respective applicable regulations and
legal requirements as well as the regulations re-
garding the local electricity and gas suppliers.
Special attention must be paid to the provisions
and guidelines that are applicable for the ventila-
tion. For conversion work to a different gas type,
we recommend that you call the after-sales ser-
vice.
¡ Ensure that the kitchen is sufficiently ventilated, in
particular when operating the gas cooking appli-
ance.
¡ Do not connect the appliance to an exhaust gas
system for combustion products.
¡ Never install the appliance in boats or in vehicles.
¡ The warranty applies only when using the appli-
ance as intended.
¡ Before installing the appliance, check that the
local conditions of the supplier are compatible
with the appliance settings specified on the rating
plate (type of gas and pressure, power, voltage).
¡ Secure the power cord to the cabinet to prevent it
from touching hot parts of the oven or hob.
¡ Before any work is carried out on the appliance,
switch off the power supply and the gas supply.
¡ Connect the appliance to the power supply using
the earth.
¡ Do not make any changes to the inside of the ap-
pliance. If required, contact our technical cus-
tomer service.
Before installing
¡ This appliance is a class 3 appliance in accord-
ance with the EN 30-1-1 standard for gas appli-
ances: Built-in appliance.
¡ The unit in which the appliance is installed must
be stable and secured appropriately.