18 | English
In addition to external influences, device-specific influences
(e.g. falls or heavy impacts) can also lead to deviations. For
this reason, check the levelling accuracy each time before
beginning work.
First check the height accuracy and levelling accuracy of the
horizontal laser line, then the levelling accuracy of the ver-
tical laser line.
Should the measuring tool exceed the maximum deviation
during one of the tests, please have it repaired by a Bosch
after-sales service.
Checking the Height Accuracy of the Horizontal Line
For this check, you will need a free measuring distance of
5m on firm ground between two walls (designated A andB).
– Mount the measuring tool close to wallA on a tripod, or
place it on a firm, level surface. Switch on the measuring
tool and select cross-line operation.
– Aim the laser at the closer wall A and allow the measuring
tool to level in. Mark the middle of the point at which the
laser lines cross on the wall (pointI).
– Turn the measuring tool 180°, allow it to level in and mark
the point where the laser lines cross on the opposite wall
B (point).
– Position the measuring tool –without rotating it– close to
wallB, switch it on and allow it to level in.
– Align the height of the measuring tool (using the tripod or
by placing objects underneath as required) so that the
point where the laser lines cross exactly hits the previ-
ously marked point on wallB.
– Turn the measuring tool 180° without adjusting the
height. Aim it at wallA such that the vertical laser line runs
through the already marked point. Allow the measuring
tool to level in and mark the point where the laser lines
cross on wallA (point).
– The discrepancy d between the two marked points and
on wallA reveals the actual height deviation of the
measuring tool.
The maximum permitted deviation on the measuring dis-
tance of 2×5m=10m is as follows:
10m×±0.3mm/m=±3mm. The discrepancy d between
points and must therefore amount to no more than
3mm.
Checking the Level Accuracy of the Horizontal Line
For this check, you will need a free area of 5×5m.
– Mount the measuring tool in the middle between wallsA
and B on a tripod, or place it on a firm, level surface.
Switch on the measuring tool and select horizontal opera-
tion. Allow the measuring tool to level in.
1 609 92A 5EN | (20.03.2020) Bosch Power Tools