English | 17
– Mark the centre of the vertical laser line
on the floor of the door opening
(pointⅠ), 5m away on the other side of
the door opening (pointⅡ) and on the
upper edge of the door opening
(pointⅢ).
– Set up the measuring tool on the other
side of the door opening, directly behind
pointⅡ. Allow the measuring tool to level
in and align the vertical laser line in such
a way that its centre passes through
pointsⅠ andⅡ exactly.
– Mark the centre of the laser line on the upper edge of the door opening as pointⅣ.
– The discrepancy d between the two marked pointsⅢ and Ⅳ reveals the actual ver-
tical deviation of the measuring tool.
– Measure the height of the door opening.
You can calculate the maximum permitted deviation as follows:
Doubled height of the door opening×0.6mm/m
Example: At a door opening height of 2m, the maximum deviation amounts to
2×2m×±0.6mm/m=±2.4mm. The pointsⅢ and Ⅳ must therefore be no further
than 2.4mm from each other.
Working Advice
u Only the centre of the laser line must be used for marking. The width of the laser
line changes depending on the distance.
Bosch Power Tools 1 609 92A 8K4 | (01.06.2023)