A9 Error - Wire Check
1. Check if the heating water sensor connector is disconnected
Figure 29
A9 Error - Exhaust Temperature Sensor Check
1. Check if the heating water sensor is defective
Defective: OL
Normal: 86 °F: 40 kΩ
140 °F: 12.4 kΩ
185 °F: 3.9 kΩ
Figure 30