Fault Cause Troubleshooting
Appliance door opens too
wide at the end of the pro-
gramme.
Door is not correctly adjus-
ted.
Adjust the appliance door as de-
scribed in the installation instruc-
tions.
The door gap must be at least
70mm - 100mm.
Wrong screws used to ad-
just the door gap.
Use size 4X30 bolts to adjust the
door gap.
The bolts are included in the scope
of supply.
If you use bolts that are too long,
this can deactivate the function of
automatic door opening.
Error code / Fault display / Signal
Fault Cause Troubleshooting
E:2130 lights up. Intake opening of Zeolith
container is covered by
items of tableware.
Re-arrange the tableware in the ap-
pliance so the "Intake opening of
the Zeolith container " →Page15
is no longer obstructed.
E:2060 lights up. Appliance has detected cal-
cified heating element.
1. Descale the appliance.
2. Operate the appliance with the wa-
ter softening system.
1
E:3000 lights up. Water protection system is
activated.
1. Turn off the water tap.
2. Call "Customer Service"
→Page60.
E:3100 lights up. Water protection system is
activated.
1. Turn off the water tap.
2. Call "Customer Service"
→Page60.
E:3400 lights up. Water is continuously run-
ning into the appliance.
1. Turn off the water tap.
2. Call "Customer Service"
→Page60.
E:3200 or indicator for wa-
ter supply lights up.
Supply hose is kinked.
Install the supply hose without
kinks.
Water tap is turned off.
Turn on the water tap.
Water tap is jammed or
furred up.
Turn on the water tap.
The flow rate must be at least 10 l/
min when the water supply is open.