Bosch Sicherheitssysteme GmbH - 1 - F.01U.045.264 | de/en/fr | A6 | 2007.03
Installationshinweise
Rauchansaugsystem
TITANUS PRO
SENS
®
TP-1 A
TITANUS PRO
SENS
®
TP-2 A
Installation Instructions
Aspirating Smoke Detector
TITANUS PRO
SENS
®
TP-1 A
TITANUS PRO
SENS
®
TP-2 A
Instructions de mise en place
Système aspirant de
détection d’incendie
TITANUS PRO
SENS
®
TP-1 A
TITANUS PRO
SENS
®
TP-2 A
1
Betriebs-LED
1
Operation LED
1
LED « en service »
2
Alarm-LED für Detektormodul 2
2
Alarm LED for detector module 2
2
LED d’alarme pour cellule de détection 2
3
Alarm-LED für Detektormodul 1
3
Alarm LED for detector module 1
3
LED d’alarme pour cellule de détection 1
4
LED Sammelstörung
4
Collective fault LED
4
LED de dérangement collectif
5
Vorgestanzte Kabeleinführungen zum
Anschluss an BMZ oder Stromversor-
gung (Ein-/Ausgang)
5
Pre-punched cable entries for connec-
tion to fire panel or power supply (in-
put/output)
5
Entrées de câbles prédécoupées pour la
connexion au tableau de signalisation
ou à l’alimentation (entrée/sortie)
6
Anschluss Rohrsystem 1
6
Connection pipe system 1
6
Raccordement canalisation 1
7
Anschluss Rohrsystem 2
7
Connection pipe system 2
7
Raccordement canalisation 2
8
Anschluss für Luftrückführung
8
Connection for air-return pipe
8
Connexion pour retour d’air
Question and Answer IconNeed help?

Do you have a question about the Bosch Titanus Pro?Sens TP-1 A and is the answer not in the manual?

Bosch Titanus Pro?Sens TP-1 A Specifications

General IconGeneral
BrandBosch
ModelTitanus Pro?Sens TP-1 A
CategorySmoke Alarm
LanguageEnglish

Summary

Detector Module Installation

Detector Module Settings

Setting Response Sensitivity

Configures detector response sensitivity levels for different detection rates.

Setting Alarm Delay

Sets the delay time before an alarm is triggered after detection.

Setting Air Flow Fault Threshold

Defines the threshold for activating the "air flow fault" condition.

Setting Air Flow Fault Delay

Sets the delay for the "air flow fault" condition.

Setting Fault Storage

Configures whether fault signals are latched or non-latched.

Setting LOGIC-SENS

Configures the LOGIC-SENS feature.

Choose Number of Detector Modules

Selects the number of detector modules installed in the device.

Setting Ventilator Voltage

Sets the fan voltage for the device's base board.

Setting Collective Fault Contact

Configures the contact type (NO/NC) for the collective fault signal.

Device Supports

Describes the available device mounting hardware options.

Device Installation

Connections and Wiring

Connection TITANUS PRO-SENS® TP-1 A

Wiring diagram for connecting the TITANUS PRO-SENS® TP-1 A to the fire panel.

Connection TITANUS PRO-SENS® TP-2 A

Wiring diagram for connecting the TITANUS PRO-SENS® TP-2 A to the fire panel.

LSN Configuration

Settings at the Detector Module

Configures detector module fault signal settings for LSN connection.

LSN Configuration with WinPara Program

LSN configuration using WinPara software for detector modules.

LSN Configuration with RPS Program

LSN configuration using RPS software for detector modules.

Initial Setup

Related product manuals