Technical data
TR4000 | TR4000R – 6 720 876 021 (2018/04)
14
4 Technical data
Type
TR4000 4
ET
TR4000R 4
ET
Undersink
TR4000 5
ET
Undersink
TR4000 6
ET
Undersink
TR4000 8
ET
Undersink
TR4000 6
EB
Over-sink
TR4000 8
EB
Over-sink
Design pressurised pressurised pressurised pressurised pressurised pressurised
Power [kW] 3,6 4,5 6 7,2 6 7,2
Electrical connection [V] 230 230 230 230 230 230
Minimum cable cross-section [mm²] 1,5 2,5 4 4 4 4
Rated current [A] 15,7 19,1 26 31,3 26 31,3
Fuse protection [A] 16 20 32 32 32 32
Water connection thread [Inch] G 3/8 G 3/8 G 3/8 G 3/8 G 1/2 G 1/2
Supply temp. max. [°C] 20 20 20 20 20 20
Warm water output at supply
temp. of 12 °C to 38 °C
[l/min] 1,9 2,4 3,2 3,9 3,2 3,9
Protection type IP 24 24 24 24 24 24
Switch on flow pressure
(without flow rate limiter)
[bar] < 0,25 < 0,25 < 0,25 < 0,25 < 0,25 < 0,25
Switch on flow [l/min] 1,8 1,8 / 1,9 1,8 / 2,1 1,8 / 2,3 1,8 / 2,1 1,8 / 2,3
Switch off flow [l/min] 1,6 1,6 / 1,7 1,6 / 2,0 1,6 / 2,2 1,6 / 2,0 1,6 / 2,2
Flow limit at [l/min] 2 2 3 4 3 4
Weight [kg] 1,1 1,1 1,1 1,1 1,1 1,1
Application area in water:
specific electric resistance
at 15 °C
[Ωcm] ≥ 1 300 ≥ 1 300 ≥ 1 300 ≥ 1 300 ≥ 1 300 ≥ 1 300
Rated pressure [MPa (bar)] 1,0 (10,0) 1,0 (10,0) 1,0 (10,0) 1,0 (10,0) 1,0 (10,0) 1,0 (10,0)
Plug-in ready
Fixed connection 
Energy efficiency class A A A A A A
Load profile XXS XXS XXS XXS XXS XXS
Annual energy consumption [kWh] 467 470 470 471 470 471
Daily energy consumption [kWh] 2,145 2,150 2,154 2,161 2,154 2,161
Sound power level [dB] 15 15 15 15 15 15
Hot water heating energy
efficiency
[%] 39,4 39,3 39,2 39,1 39,2 39,1