EasyManua.ls Logo

Bosch WTD 12-4 AME 23 - User Manual

Bosch WTD 12-4 AME 23
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Page 1 from 45 6 720 887 546 “SM FP_ErP LPP/MPP Europe 2018/05 en”
LOW NOX INSTANTANEOUS
GAS WATER HEATER
ROOM SEALED FAN ASSISTED / PRESSURIZED
GAS WATER HEATER
FOR INDOOR INSTALLATION
TRAINING AND SERVICE INFORMATION FOR AFTER SALES
This document is restricted to exclusive use by the official service partners. Each
country should adapt the manual and its contents to the available range.

Other manuals for Bosch WTD 12-4 AME 23

Questions and Answers

  • J
    James RodriguezSep 18, 2025
    What to do if my Bosch WTD 12-4 AME 23 Water Heater indicates a gas valve wrong connection?
    • S
      Steven FoxSep 18, 2025
      If a safety solenoid from the gas valve is disconnected, it indicates a gas valve wrong connection. The error is resolved by performing a manual reset.
  • K
    katherine94Aug 25, 2025
    What to do if my Bosch WTD 12-4 AME 23 Water Heater has exhaust blockage?
    • P
      parkjamieAug 25, 2025
      If the fan speed and/or consumption detect a pressure above normal operating conditions on the exhaust, check configuration parameters like AS (altitude), F9 (flue exhaust code), AP (appliance power), etc.
  • S
    Sarah AndrewsAug 25, 2025
    What to do if my Bosch WTD 12-4 AME 23 shows temperature limiter or thermal fuse opened circuit?
    • C
      costakeithAug 26, 2025
      This error occurs if the temperature limiter detects a temperature over 85ºC, or if the thermal fuse contact opens (192ºC) due to overheating and malfunction of the temperature limiter. The error is resolved by manually resetting the system after the temperature limiter cools down and the contact closes again.
  • J
    James WilsonAug 27, 2025
    Why does my Bosch Water Heater display a water flow signal over specified maximum value?
    • S
      shelleymillerAug 27, 2025
      This error occurs when the water flow exceeds 22 l/min. The error is resolved when the water flow is below this value again.
  • C
    Crystal Mcfarland MDSep 22, 2025
    What causes an exhaust blockage error in my Bosch WTD 12-4 AME 23 Water Heater?
    • L
      Lisa HarrellSep 22, 2025
      If pressure above normal operating conditions is detected, it indicates an exhaust blockage. The error is resolved by performing a manual reset.
  • J
    John GonzalezSep 23, 2025
    What does MCU RAM DC internal error mean for my Bosch WTD 12-4 AME 23 Water Heater?
    • R
      Ricardo FinleySep 23, 2025
      If voltage is too low (less than 70 V ac), it triggers an MCU RAM DC (micro controller) internal error. The error is resolved by performing a manual reset.
  • J
    joyceedwardSep 9, 2025
    What does it mean when my Bosch WTD 12-4 AME 23 displays MCU RAM DC (micro controller) internal error?
    • K
      Kathleen PhelpsSep 10, 2025
      Check if the voltage is too low (less than 70V AC). This error is resolved by a manual reset. If the voltage is okay and the error persists, replace the control unit.
  • J
    johnsonphilipSep 12, 2025
    Why does my Bosch WTD 12-4 AME 23 show an error related to the temperature limiter or thermal fuse?
    • R
      roachamandaSep 12, 2025
      If the temperature limiter detects a temperature over 85ºC, it causes the temperature limiter or thermal fuse to open the circuit. This error is resolved by manually resetting the system after the temperature limiter cools down and the contact closes again.
  • A
    Angela WiseSep 3, 2025
    What to do if my Bosch WTD 12-4 AME 23 displays an internal checking failure?
    • P
      paulpetersonSep 3, 2025
      This error is resolved by a manual reset. If the error persists, replace the control unit.
  • K
    Kimberly DavisSep 1, 2025
    What to do if my Bosch WTD 12-4 AME 23 remote controller removes the error code 5 times continuously within 15mins?
    • J
      Joy WilliamsSep 1, 2025
      This error is resolved by a manual reset.

Summary

Installation Procedures

Components Overview

Control Panel

Explains the function and usage of the control panel interface.

Heat Cell with Burner Pipes

Details the heat cell, heat exchanger, burner, ignition, and ionization electrodes.

Gas Manifold

Explains the gas manifold design, injectors, and burner operation.

Gas Valve

Explains the modulating gas valve for controlling gas flow and thermal load.

Heat Exchanger

Details the copper heat exchanger, its configuration, and protection.

Water Flow Sensor

Details the turbine flow sensor and its characteristic curve for flow measurement.

Ignition Electrode

Explains the ignition process, safety time, and retry sequences.

Ionization Electrode

Describes the ionization electrode for flame detection and confirmation.

Working Principle and Electric Measurements

Overview of ECU (Electronic Control Unit) MPP

Diagram of the electronic control unit (ECU) for MPP models.

Overview of ECU (Electronic Control Unit) LPP

Diagram of the electronic control unit (ECU) for LPP models.

Service Procedures

Procedure to Enter Service Mode

Step-by-step guide to access and navigate the appliance's service mode.

Service Mode Parameters List (Technician Level)

Comprehensive list of service mode parameters for technician use.

P4 Diagnostic Mode Parameters List

Lists parameters available for diagnostic mode (P4) for analysis.

Gas Power Adjustment Parameters

Maintenance Recommendations

Trouble Shooting Guide

Bosch WTD 12-4 AME 23 Specifications

General IconGeneral
Water ConnectionG 1/2"
Fuel TypeNatural Gas
Gas ConnectionG 1/2"
Frequency50 Hz
Weight23 kg

Related product manuals