Page 1 from 45 6 720 887 546 “SM FP_ErP LPP/MPP Europe 2018/05 en”
LOW NOX INSTANTANEOUS
GAS WATER HEATER
ROOM SEALED FAN ASSISTED / PRESSURIZED
GAS WATER HEATER
FOR INDOOR INSTALLATION
TRAINING AND SERVICE INFORMATION FOR AFTER SALES
This document is restricted to exclusive use by the official service partners. Each
country should adapt the manual and its contents to the available range.

Other manuals for Bosch WTD 15-3 AME 31

Questions and Answers

  • M
    Michael HollandSep 18, 2025
    What to do if my Bosch Water Heater indicates a gas valve wrong connection?
    • W
      williamblackSep 18, 2025
      If a safety solenoid from the gas valve is disconnected, it indicates a gas valve wrong connection. The error is resolved by performing a manual reset.
  • Y
    youngdonaldAug 25, 2025
    What to do if my Bosch WTD 15-3 AME 31 Water Heater has exhaust blockage?
    • S
      Shawn ReevesAug 25, 2025
      If the fan speed and/or consumption detect a pressure above normal operating conditions on the exhaust, check configuration parameters like AS (altitude), F9 (flue exhaust code), AP (appliance power), etc.
  • W
    wkiddAug 25, 2025
    What to do if my Bosch WTD 15-3 AME 31 shows temperature limiter or thermal fuse opened circuit?
    • N
      nicolevargasAug 26, 2025
      This error occurs if the temperature limiter detects a temperature over 85ºC, or if the thermal fuse contact opens (192ºC) due to overheating and malfunction of the temperature limiter. The error is resolved by manually resetting the system after the temperature limiter cools down and the contact closes again.
  • H
    Holly VelasquezAug 27, 2025
    Why does my Bosch Water Heater display a water flow signal over specified maximum value?
    • D
      deleonmadisonAug 27, 2025
      This error occurs when the water flow exceeds 22 l/min. The error is resolved when the water flow is below this value again.
  • J
    Justin FloresSep 22, 2025
    What causes an exhaust blockage error in my Bosch WTD 15-3 AME 31 Water Heater?
    • L
      lamjasonSep 22, 2025
      If pressure above normal operating conditions is detected, it indicates an exhaust blockage. The error is resolved by performing a manual reset.
  • J
    John CarsonSep 23, 2025
    What does MCU RAM DC internal error mean for my Bosch Water Heater?
    • M
      Mr. Jesus CopelandSep 23, 2025
      If voltage is too low (less than 70 V ac), it triggers an MCU RAM DC (micro controller) internal error. The error is resolved by performing a manual reset.
  • G
    gabriela61Sep 9, 2025
    What does it mean when my Bosch Water Heater displays MCU RAM DC (micro controller) internal error?
    • J
      John MeyerSep 10, 2025
      Check if the voltage is too low (less than 70V AC). This error is resolved by a manual reset. If the voltage is okay and the error persists, replace the control unit.
  • K
    Kara DawsonSep 12, 2025
    Why does my Bosch Water Heater show an error related to the temperature limiter or thermal fuse?
    • M
      Misty StevensSep 12, 2025
      If the temperature limiter detects a temperature over 85ºC, it causes the temperature limiter or thermal fuse to open the circuit. This error is resolved by manually resetting the system after the temperature limiter cools down and the contact closes again.
  • J
    John McfarlandSep 3, 2025
    What to do if my Bosch Water Heater displays an internal checking failure?
    • J
      James GoldenSep 3, 2025
      This error is resolved by a manual reset. If the error persists, replace the control unit.
  • N
    nicole22Sep 1, 2025
    What to do if my Bosch WTD 15-3 AME 31 Water Heater remote controller removes the error code 5 times continuously within 15mins?
    • C
      Collin HicksSep 1, 2025
      This error is resolved by a manual reset.

Summary

Installation and Setup Guide

Appliance Wall Mounting Requirements

Details requirements and checklist for securing the appliance to the wall.

Water and Gas Connection Procedures

Checklists for ensuring proper water and gas connections.

Flue Exhaustion Configuration

Guidelines for flue length configuration based on model and orientation.

Components Overview and Functionality

Ignition Electrode Function

Explains the ignition sequence, safety time, and attempts for spark generation.

Ionization Electrode Function

Describes sensing flame via ionization electrode and detection thresholds.

Working Principle and Operation

Operational Modes and Safety

Power Reduction for High Temperature Risk

Details how the appliance reduces power to prevent overheating and scalding.

Power Reduction at Start-up

Explains power reduction during start-up to avoid overheating with low water flow.

Service Mode Access

Gas Power Adjustment Parameters

Maintenance and Cleaning

Troubleshooting and Error Code Resolution

Error Code Definitions and Types

Lists error codes, definitions, and types for troubleshooting appliance issues.

Bosch WTD 15-3 AME 31 Specifications

General IconGeneral
TypeGas Water Heater
MountingWall Mounted
Hot Water Output15 L/min
IgnitionElectronic Ignition
Voltage230 V
Frequency50 Hz
ThermostatYes
Safety FeaturesFlame Failure Device, Overheat Protection
Weight13 kg
Gas TypeNatural Gas
CapacityInstantaneous