2.3 Mounting the detector
Use the hardware provided. The plastic mounting anchors
require a 3/16 (5 mm) hole.
Surface mounting
1 Tamper Screw
Corner Mounting
2.4 Wiring the detector
Wire sizes between 16 AWG and 26 AWG (0.2 mm
2
and 1
mm
2
) are permitted. Install the wiring using the approprate
knock-outs and tie-downs.
© 2009 Bosch Security Systems, Inc. 3
2.5 Wiring the terminal blocks
The detector has two terminal blocks. One block is used for
primary wiring; the other has two spare terminals. The two
spare terminals are normally used as tie points for the EOL
resistor.
     



 






Do not attempt to remove the terminal blocks from
the cover. This could result in permanent damage
to the detector.