EasyManua.ls Logo

Bosch ZWB 42-3 A NG - Examples of Installations; Multiple Zones Using Zone Valves with DHW

Bosch ZWB 42-3 A NG
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Examples of Installations
25
Greenstar – 6721822579 (2021/01)
5 Examples of Installations
5.1 Multiple zones using zone valves with DHW
Fig. 9 Piping
[1] Motorized valve heating zone 2
[2] To heating zone 2
[3] Bosch room temperature controller heating zone 2 (CRC100)
[4] Motorized valve heating zone 1
[5] To heating zone 1
[6] Bosch controller heating zone 1 and DHW (CRC200)
[7] System pump
[8] DHW pump
[9] To indirect tank
[10] Comfort Zone Module CZM100
[11] External system supply temperature sensor for system supply
pipe (to be installed in closest vicinity with boiler supply Tee)
[12] Boiler primary line - supply pipe 1"
[13] Boiler primary line - return pipe 1"
[14] Heating boiler ZBR...-3A
[15] From indirect tank
[16] From heating zone 1
[17] From heating zone 2
[18] Expansion vessel
X 4 × pipe diameters on boiler primary side (here ≤ 4 × 1")
For all accessories not included in the package please refer to the Bosch
Product Catalog.
ϑ
MM
2
3 6
5
9
7
8
X
1615 17
13
1
4
14
18
10
12
11
6 720 806 992-03.2O

Table of Contents