EasyManua.ls Logo

Bosch ZWB35-3A Series - Information About the Appliance

Bosch ZWB35-3A Series
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Information about the appliance | 7
6 720 806 992 (2015/03)Greenstar
3 Information about the appliance
ZBR appliances are residential boilers for central heating and loading of
an indirect fired DHW tank.
ZWB appliances are residential combi boilers for central heating and on
demand DHW heating.
The appliances comply with South Coast Air Quality Management
District (SCAQMD) 2012 requirements: (Type-1) 14 Ng/J NO
x
(and/or
20 ppm at 3% O
2
).
3.1 Proper use
The Greenstar boiler is not for use in CSD-1 commercial installation.
The appliance may only be installed in closed loop hot water central
heating systems.
Any other purpose is considered improper use. Any resulting damage is
excluded from the manufacturer's warranty.
The commercial and industrial use of the appliance for generating
process heat is not permitted.
3.2 Overview of boiler types
Table 2 describes the meaning of the model number:
Z Central heating appliance
W DHW heating
B Condensing technology
R Constant temperature control
16 Output up to 54,600 BTU/hr (16 kW)
21 Output and DHW output up to 71,600 BTU/hr (21 kW)
28 Output and DHW output up to 95,500 BTU/hr (28 kW)
35 Output and DHW output up to 119,400 BTU/hr (35 kW)
42 Output and DHW output up to 143,300 BTU/hr (42 kW)
-3 Version
A Fan-supported appliance
23 Natural gas (NG)
3.3 Rating plate
The rating plate is located at the right side of the appliance.
Fig. 3 Position of the rating plate
The rating plate contains the appliance output, model number, approval
data and serial number.
3.4 Appliance description
Appliance for wall installation, regardless of chimney and room size
Outdoor reset control FW 200
Intelligent boiler pump control
Heatronic boiler control with 2-wire BUS
Three-speed boiler circulator
Automatic air vent (combi boiler ZWB..-3A only)
Display
Automatic ignition
Continuously-controlled output
Full protection via the Heatronic with flame rod and solenoid valves
No minimum circulating water flow rate required
Suitable for radiant floor heating
Flue adapter for flue gas and combustion air with test ports
Variable speed fan
Gas premix burner
Temperature sensor and temperature control for space heating
Supply temperature sensor
Temperature limiter
Safety relief valve, pressure gauge
Expansion vessel (combi boiler ZWB..-3A only)
Connection possibility for DHW tank temperature sensor (NTC)
(heating boiler ZBR..-3A only)
Flue gas temperature limiter
DHW priority (combi boiler ZWB..-3A only)
Motorized 3-way valve (combi boiler ZWB..-3A only)
Hydraulics connection plate
ZBR16-3 A 23
ZBR21-3 A 23
ZBR28-3 A 23
ZBR35-3 A 23
ZBR42-3 A 23
ZWB28-3 A 23
ZWB35-3 A 23
ZWB42-3 A 23
Table 2 Appliance types
6 720 641 933-84.2O

Table of Contents