FUNCTIONAL TEST PROCEDURES
Required Equipment
Audio Sweep Generator
L2400 Power Amplier
1. Air Leak Test
1.1 Apply a 50 Hz, 10 Vrms tone signal to the
unit’s PARALLEL (left) input.
1.2 Listen for any air leaks from sealed areas
such as the Grille Assy and Cup Pole.
2. Buzz and Sweep Test
2.1 Apply a 20 Vrms signal to the unit’s
PARALLEL (left) input.
2.2 Sweep the generator from 40 Hz to 200
Hz, input sweep sine wave to power amplier
(Filter: none).
2.3 Duration Time is 10s -10s and Listening
Distance is 60cm.
2.4 Listen for buzz, rub, or extraneous sounds.
Localize and repair any buzz. Replace any
Woofer that rubs or produces extraneous
sounds.