EasyManua.ls Logo

Bosean Electronic Technology K-600 - 4. Operation & Function; 4.1 Turn on self check and preheating process

Bosean Electronic Technology K-600
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Bosean Electronic Technology Co.,Ltd www.bosean.com
Tel:86-371-86533226 Email: sales03@bosean.com
- 3 -
Gas sampling method: Gas pump sampling
Detecting gas: Combustible gas, H2S, CO, O2
Accuracy: ≤±5% F.S.
Response Time: ≤30s
Indication: LCD displays real-time and system status;
LED, audio and vibration alert for gas leakage, fault and low
voltage, pump working state.
Working environment: -20℃~50℃, <95%RH (no dew)
Power Source: DC3.7V Li-on battery, 3200mAh
Charging time: 6h~8h
Working time: ≥ 8h continuously (without alarming)
Gas Sensor Life: 2 years
Explosion-proof grade: Ex ib IIB T4 Gb
Protection Grade: IP65
Weight: Appr. 400g (with battery)
Dimensions: 130mm×67mm×30mm(L × W × H)
4. Operation & Function
4.1 Turn on self check and preheating process
Press the button for 4s and then release it. the LCD
screen of the detector is turned on and the welcome interface is
displayed. The detector automatically performs self-test of the
sound, light and vibration alarm signals, displays the system
information and performs the preheating countdown. The above
information can be used to confirm the integrity of the detector
performance.
4.1.1 After the detector is warmed up and
enters the power-on state, the normal detection
state of the detector is shown in Figure 1. (The
display mode varies according to the position of
the sensor, and the gas in the figure represents
methane.) Fig.1