Do you have a question about the Bostitch CAP60PB-OF and is the answer not in the manual?
Brand | Bostitch |
---|---|
Model | CAP60PB-OF |
Category | Air Compressor |
Language | English |
Users must read and understand manual information before operation, assembly, or maintenance.
Keep body parts, hair, clothing, and jewelry away from moving parts. Ensure guards are in place.
Do not exceed pressure ratings of attachments. Exceeding can cause explosion and serious injury.
Wear ANSI Z87.1-1989 eye protection. Hearing/head protection may be needed in some environments.
Use handle to move. Do not drag by cord or hose. Disconnect before transporting.
Drain moisture daily to prevent rust and thinning. Failure can cause explosion and serious injury.
Risk of fire/explosion. Do not spray flammable liquid in confined areas. Ensure ventilation.
Compressor generates heat. Avoid touching hot cylinder head parts or tubing during/after operation.
Ensure proper grounding to reduce shock risk. Use adapter only temporarily if needed.
Motor has overload protector. It shuts off motor if overheated and restarts when cool.
Use On/Off switch, not plug, to stop. Avoid restarting against high pressure to prevent motor damage.
Valve is factory set at 150 PSI to prevent over-pressurization. Do not adjust or eliminate.
Do not operate over 50% duty cycle for long life. Match air volume needs to compressor delivery.
Extension cords can cause voltage loss. Use recommended gauge for distance; avoid long cords.
Activates motor to start/stop compressor based on tank pressure, cycling automatically.
Indicates the air pressure present in the tank in PSI.
Shows pressure allowed into the discharge line based on regulator setting.
Adjusts discharge air pressure by turning clockwise (increase) or counter-clockwise (decrease).
Twist-style valve used to drain moisture from the tank when opened.
Inspect for damage, verify tanks are drained and clear of moisture or dirt.
Ensure switch is Off, pressure is 0 PSI, attach hose, plug in, pull switch to On, adjust regulator.
Push in the On/Off switch to the Off position.
Disconnect accessories and power before service. Use only genuine parts. Oil-free pump.
Turn compressor Off, tilt toward drain cock, open valve, and drain all moisture.
Check tank pressure, extension cord, fuse, or switch position. Ensure unit is plugged in.
Check fittings and pressure switch for leaks. Tighten fittings, check with soapy water.
Check for cold weather, loose fittings, clogged valve, high demand, loose head, or gasket issues.
Check for damaged air tank. WARNING: Do not drill, weld, or modify tank; replace if damaged.