FREELINK™ REMOTE CONTROL
HANDBOOK
SC-5270 Freelink Remote Control
SC-5572-1 and SC-5572-1A Freelink Remote
Control Kit
92395657-01
Content: MP92395657-01 REV B
55
%
1
Morning
Level
Main Menu
i-Sculpt
Restore to
Clinic Settings
SelectBack
Spread
EGL Scan
French
Accept
Spread
120
µS
Strength
Programs
Programs
P
Stimulation Areas
Main Menu
System Settings
Programs
Stimulation Areas
Main Menu
System Settings
Programs
Stimulation Areas
Main Menu
System Settings
Morning
1
Night
2
Program 3
3
4
Options
Change Programs
Program / copy to: Available program slot
Active Program
Empty Program Slot / copy to: Clinician program can not be overwritten
Save
Copy to ...
Copy to ...
Delete
Program
Activated
Program
Saved
Program
Restored
Program
Deleted
Yes
No
Restore
Program 1
‘Morning
to Clinic Settings?
Yes
No
Overwrite
Program 4
‘Empty
Yes
No
Delete
‘Program 3’ ?
Stimulation Areas Lower Back
Lower Back
A
Hip
B
Left Leg
C
Left Leg 2
D
Sensation
i-Sculpt
Compare
Lower Back
Strength
4.6
mA
Lower Back
Sensation
200
Hz
Lower BackLower Back
Return to i-Sculpt
Discard and Exit
Compare to Old
Lower Back
Stimulating
New
Settings
Yes
No
Lower Back
Discard
Changes to
‘Lower Back’?
Yes
No
Lower Back
Accept
Changes to
‘Lower Back’?
Press
Side Button
to Unlock
Stimulation
OFF
Stimulation
ON
Unlock
All top bars change to red when Adv. Mode is activated.
Home
Programs
P
System Settings
Remote Settings
System Info
Clinician Mode
Remote Settings
Alert Volume
Screen Brightness
Languages
Alert Volume Screen Brightness
Alert VolumeScreen Brightness
Italian
Spanish
Languages
German
SelectBack
English
English
selected
System Info
Remote Info
Implant Info
Impedances
Remote Info
Serial Number
SC-508392938
Battery Voltage
4.5 V
Battery Status
?
Firmware Version
1.2
Implant Info
Serial Number
SC-508392938
Battery Voltage
4.5 V
Battery Status
?
Implant Type
1.2
Implant Info
Lead Type
M-2357
IPG Temperature
40.3 C
Battery Impedance
?
Reset Counter
1.2
Impedances
1234
1234
1234
1234
1234
1234
1234
1234
1
2
3
4
5
6
7
8
1234
1234
1234
1234
1234
1234
1234
1234
Info
Info
-
Telemetry Test
Info
-
9
10
11
12
13
14
15
16
1234
1234
1234
1234
1234
1234
1234
1234
1
2
3
4
5
6
7
8
1234
1234
1234
1234
1234
1234
1234
1234
9
10
11
12
13
14
15
16
Impedances
EGL Scan
Rescan
Cancel Cancel
4.5
EGL Scan
Rescan
-
Main Menu
85
%
1
Morning
Level
IPG Charge Test
Coil
Detected
Coil Frequency
0123456
Peak Current Found
0123456
ADC
0123456
+-
Single Lead
Selected
Yes
No
Enable
EGL Scan
for iSculpt?
Password Clinician Mode
Adv. Mode: ON
Diagnostics
Impedances
CP Mode
Lock-Out
Clear Link
EGL Scan
Lower Back
Clear Link
to Stimulator
ID 123456
Clear Link
Yes
No
Link This Remote
to Stimulator
ID 123456
Link
Yes
No
Diagnostics
Button Test
LCD Test
Telemetry Test
IPG Charge Test
Select
Lock Out
Spread
Sensation
i-Sculpt
Advanced User
Feeling egarevoChtgnertS aerA
SelectBack
SelectBack
SelectBack SelectBack
SelectBack SelectBack SelectBack
SelectBack
SelectBack SelectBack
SelectBack
Back
Strength
4.6
mA
Back
Back
Back
Select SelectBackReturn SelectBack SelectBack
SelectBack
SelectBack SelectBack
Back Back
Back
Back
MoreBack Back
Back Back
MeasureBack
MeasureBack
SelectBack SelectBack
SelectBack SelectBack
SelectBack
SelectBack SelectBack
Empty
5
Programs
Morning
1
Night
2
Program 3
3
Empty
4
SelectBack
1 1 1
55
%
1
1
Morning
Level
Main Menu
Stimulation
ON
Stimulation
ON
Stimulation
OFF
Stimulation
OFF
Stimulation
ON
Stimulation
OFF
1 1 1 1 1 1
Compare to New
Lower Back
Stimulating
Old
Settings
SelectBack
1 1 11
4.6
mA
Lower Back
1
Finish
Scroll
Select / Next
Backspace
1
P
A _ _ _ _
Option A Option B Option C
CAUTION: Federal law restricts this device to sale,
distribution and use by or on the order of a physician
92395657-01

Other manuals for Boston Scientific Freelink SC-5270

Question and Answer IconNeed help?

Do you have a question about the Boston Scientific Freelink SC-5270 and is the answer not in the manual?

Boston Scientific Freelink SC-5270 Specifications

General IconGeneral
ModelFreelink SC-5270
CategoryRemote Control
ManufacturerBoston Scientific
CompatibilityBoston Scientific Implantable Devices
Battery TypeLithium
CommunicationWireless

Summary

Introduction to the Freelink Remote Control

Cautions

Important safety precautions for using the Freelink RC, including dryness and handling.

Remote Control Buttons

Description and location of all physical buttons on the Freelink Remote Control.

Using the Remote Control

Checking Stimulation Therapy Status

How to verify if stimulation therapy is active using the RC's status indicators.

Turn Stimulation Therapy ON/OFF

Step-by-step instructions on how to turn the stimulation therapy on and off via the RC.

Adjust Stimulation Strength

Guide on how to increase or decrease the stimulation intensity using the RC buttons.

Recharging the Remote Control

Instructions for connecting the RC to the power supply for recharging the battery.

Using Programs

Save a Program

Instructions on how to save customized Program settings as default.

Using Schedules

Activate or Change Schedules

How to select and switch between different therapy Schedules.

Configuring Stimulation Areas

Change a Stimulation Area Parameter

Instructions on adjusting parameters like Amplitude, Pulse Width, and Rate for a Stimulation Area.

About MRI Mode

Enabling MRI Mode

Step-by-step instructions to activate MRI Mode on the Stimulator and RC.

Disabling MRI Mode

Procedure to safely exit MRI Mode after an MRI scan.

MRI Mode Error Messages (Rechargeable Stimulators Only)

Explains error messages related to MRI Mode for rechargeable stimulators.

MRI Mode Error Messages (Non-Rechargeable Stimulators Only)

Explains error messages related to MRI Mode for non-rechargeable stimulators.

MRI Mode Error Messages

Details on error messages encountered during MRI Mode, such as impedance issues.

Troubleshooting

Unlinked RC

Steps to link the RC to the Stimulator if they are not paired.

System Settings Reset Screen

How to reset RC settings to factory defaults due to an error.

Stimulator Error Screen

Message indicating a non-critical error with the Stimulator.