67
M21-M26-M30
11. Maintenance 11.
Disposing of the machine
Drain cartridge filter.
Allow cartridge to drip dry and dispose of it.
Drain Economy filter
Remove, clean and dry filter discs
Empty water separator, operating material tank, extraction tank and operating material cooler
(dispose of process water, decant solvent).
Empty out process water tank, dispose of process water.
Empty tanks. You can draw off the solvent residue by tilting the machine and attaching one end of a
flexible suction tube to an external pump and inserting the other end through the sight-glass opening.
Empty condenser.
Empty out solvent pump and vacuum pump, do not leave any solvent residue in the base of the
pump
Empty and clean the still when it is cold, dispose of residues.
Pump cooling agent out of the refrigeration unit
(done by authorized customer service technician).
Close open solvent lines tightly when disassembling the machine.
You must completely remove all residues that could present a hazard to people and the environment,
Observe safety regulations concerning the handling of solvent (see Point 2).