General Precautions
•Readtheinstructionscarefullybeforestartinginstallation
andproceedasspeciedbythemanufacturer;
•Installation,programming,commissioningandmainte-
nanceoftheproductmustonlybeperformedbyqualied
technicianswhohavebeenproperlytrainedincompliance
withcurrentstandards,includinghealthandsafetyregu-
lations;
•Theelectroniccardscanbeseriouslydamagedbydischar-
gesofstaticelectricity:iftheyaretobehandled,wear
suitableclothingandanti-staticfootwear,oratleast,
ensurestaticelectricityhasbeendischargedbytouching
withthengertipametallicsurfaceconnectedtotheearth
system(e.g.thechassisofahouseholdappliance);
•Beforeperforminganycleaningormaintenanceoperation,
disconnectthepowersupplytothedevice;
•Theequipmentmustonlybeusedforthepurposefor
whichitwasexplicitlydesigned.
•Themanufacturerdeclinesallliabilityforanydamageas
aresultofimproper,incorrectorunreasonableuse.
Installation B
ThepowersupplyunitmustALWAYSbeinstalledhori-
zontally.TheequipmentcanbeinstalledonDINrails(EN
50022)a,onasuitableswitchboard,oronthewallusing
theterminalcovers.
Todismantleit,proceedasshowningurec.
NOTE. Proper ventilation is required if the power sup-
plier is installed in a metal container.
Technical data
Type VA/01
Powersupply[V
AC
] 230
Maxcurrentdemand[A
AC
] 0,35
Maxenergydissipation[W] 25
Entrypanelsnominalpowersupply[V
DC
] 18
Entrypanelscurrentdemand[A] 0,6
Entrypanelspeakpowersupply[V
DC
] 18
Entrypanelspeakcurrentdemand[A] 1,1<15’’(*)
Risingcablepowersupply[V
DC
] 20
Risingcablecurrentdemand[A] 0.8for1’
Risingcablecurrentdemand[A] 0.2for3’
Dimensions[DIN] 12
Storagetemperature[°C] -25÷+70
Operatingtemperature[°C] 0÷+35
Protectionrating[IP] 30
(*)1.6A<15’’withrisingcablenotconnectedorcon-
nectedseparately.
Functions C
Terminal boards a
~
Mains
~
Aux1outputOpenCollectormax100mA
+12V Common
Aux2outputOpenCollectormax100mA
+
–
Entrypanelpowersupply18VDC(*)
BIN1 BUSlineinputfromentrypanel1
BIN2 BUSlineinputfromentrypanel2
BIN3 BUSlineinputfromentrypanel3
BOUT Busbaroutput
(*)Theapplianceiselectronicallyprotectedagainstover-
loadsandshortcircuits.
Connectors
c RS232:Reservedforfutureuse.
MINI USB:ConnectorforprogrammingfromaPC
Pulsante PROG (**)
RFID PROG Jumper (**)
RFID
Default Codeentry Codedeletion
LED
Colour Meaning
DL1
(**)
Yellow Programmingstatus
DL2
Green USBconnected
(**)Refertothe“ProgrammingManualforEntryPanels
DC/01-DVC/01-DC/01ME-DVC/01ME”.
Absorption D E
aWithentrypanels‘onstandby’
Withsurveillancecameraon
c Withsolenoidlock‘on’
Distances G
aVCM/2D
L1,L2,L3≤100m;
L1+L2+L3≤300m.
VCM/1D
La+Le≤100m;
Lb+Le≤100m;
Lc+Le≤100m;
Ld+Le≤100m;
La+Le+L1(L2,L3)≤150m;
Lb+Le+L1(L2,L3)≤150m;
Lc+Le+L1(L2,L3)≤150m;
La+Lb+Lc+Ld+Le+L1+L2+L3
≤600m.
Programming
Of an intercom group H
y Programming the intercom group must be done
after assigning the type of call key or call code to all
the internal receivers.
Pressthepowersupply’sPROGkeyforatleast25seconds,
untilthePROGLEDashesquicklyaandthenputthe
RFIDjumperinposition“+” .
Toenabletheintercomfunction,swipeontheinternal
receiverthatyouwanttoprogramme,andpressthecall
buttonyouwanttocallfrom:abeepwillsoundtoshow
thatprogramminghastakenplacec.
Continuebyrepeatingthesameoperationsforalltheother
internalreceiverstobeincludedintheintercomgroup.
Toleaveprogramming,brieflypressthepowersupply’s
PROGkey andputtheRFIDPROGjumperinthedefault
position.
NOTE.Ifnoactionisperformed,theprocedurewillauto-
maticallyendafter30minutes.
Onceaninternalreceiverhasbeenincludedinanintercom
groupbyassigningthecallkey,itcannolongerbeexcluded
fromthatgroup.
Tochangethecallkeyofaninternalreceiverthathas
alreadybeenprogrammedtohavetheintercomfacility,
andthereforeaddnewinternalreceiverstothegroup,just
repeatthesequenceofoperationsdescribedabove.
Deactivating the intercom facility I
Pressthepowersupply’sPROGkeyforatleast25seconds,
untilthePROGLEDashesaandthenputtheRFIDPROG
jumperinposition“+”foratleast20seconds.Atthe
endofthattime,puttheRFIDPROGjumperinthedefault
position,toleaveprogrammingc.
Connection examples F L
Onegroupofintercommunicatinginternalreceiverscanbe
programmedwiththeVA/01powersupply,followingthe
procedurejustdescribed.Ifyouneedtoconguremore
thanoneintercomgroupVSE/301devicesmustbeused.
YoucannotcongureoneintercomgroupwithVA/01and
otherswithVSE/301atthesametimeL .
DISPOSAL
Donotlittertheenvironmentwithpackingmaterial:make
sureitisdisposedofaccordingtotheregulationsinforce
inthecountrywheretheproductisused.
Whentheequipmentreachestheendofitslifecycle,take
measurestoensureitisnotdiscardedintheenvironment.
Theequipmentmustbedisposedofincompliancewith
theregulationsinforce,recyclingitscomponentparts
whereverpossible.
Componentsthatqualifyasrecyclablewastefeaturethe
relevantsymbolandthematerial’sabbreviation.