Bradyprinter 200M-PLUS User’s Guide 13
$XWR&DOLEUDWLRQ
When auto calibrating, the printer determines the label length and media/ribbon sensor
settings.
Auto calibration occurs when the printer is turned on and each time the printer
recovers from an error condition. (To clear an error, open and close the printhead
assembly and then press the PAUSE key.) The printer begins to auto calibrate when
all errors have been cleared.
The results of the auto calibration are stored in the printers memory and are retained
even if printer power is removed. These parameters remain in effect until the next
calibration is performed.
NOTE: The auto calibration process does not take place if the ZPL command
or front panel setting for “MEDIA POWER UP” or “HEAD CLOSE” is set to
either “feed” or “no motion.” In these cases, the printer assumes the media is
correctly positioned and starts printing without auto calibrating.