EasyManua.ls Logo

Brainchild VR18 - 6 Application Examples

Brainchild VR18
91 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
78
6. Application examples
Example 1: Flow measurement
A level has to be converted into a flow according to the following formula.
Q ( calculated flow speed in liter per minute ) = 0.0072*h *60
h ( level range in mbar per second ) = 0 – 30 mbar
In 4.1 Channel Mode of Configuration, set AI1 as follows,
Name: Level 1 Desc: xxxxxx
Method: Instant Speed: 1 S ( 1 second / data )
Offset: 0.00 Gain: 1.000
Sensor: Current Unit: mA Range: 4.0 20.0
Scale Unit: mbar Low: 0.00 High: 30.00
Press Math to get into Math Channel and set Math1 as follows,
Name: Flow 1 Desc: xxxxxx
Type: Enable Log Method: Instant Speed: 1 S
Expression: 0.0072*AI1^2.5*60
Unit: l/min Low: 0.0 High: 2200.0
Example 2: 8:00 am start logging, 17:00 pm stop logging Monday-Friday
Select Tools mode of Configuration, and define Timer 1 – 4 as follows,
Timer 1 Timer 2
Type: Daily Action: Enable Type: Daily Action: Enable
Time: 8 Hour 0 Min. Time: 17 Hour 0 Min.
Job 1: Start logging Job 1: Stop logging
Timer 3 Timer 4
Type: Weekly Action: Enable Type: Weekly Action: Enable
Time: Saturday 8 Hour 1 Min Time: Sunday 8 Hour 1 Min
Job1: Stop logging Job1: Stop logging

Related product manuals