EasyManua.ls Logo

Breckwell Tradition P23FSA - User Manual

Breckwell Tradition P23FSA
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED
Manufactured by
Breckwell Hearth Products
Eugene, Oregon
Grand Prairie, Texas
OWNER’S MANUAL
TRADITION SERIES P23
BRECKWELL HEARTH PRODUCTS
C-L-068 7/04
P23FSL P23I P23FSA
WARNING
: If your appliance is not properly installed a house fire may result. For your safety,
follow the installation directions. Contact local building or fire officials about restrictions and
installation inspection requirements in your area.
PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater.
Failure to follow these instructions could result in property damage, bodily injury, or even death.
Save these instructions.

Questions and Answers

  • B
    Brandon MccannAug 9, 2025
    Why does the glass soot up so fast on my Breckwell Tradition P23FSA?
    • D
      Deanna McguireAug 9, 2025
      The glass on your Breckwell stove may be sooting up quickly due to several reasons. The stove or vent pipe might be dirty, restricting airflow. The vent pipe could be improperly installed. The air damper might be set too far in, or it could be broken. Blocked burnpot holes or a blockage in the air intake pipe could also be the cause. A circuit board malfunction or a combustion blower that isn't spinning fast enough could also contribute to this issue. Alternatively, the pellets being used may be of poor quality, or the trim setting on the low feed rate may be too low.
  • D
    Douglas PaceAug 14, 2025
    What to do if my Breckwell Tradition P23FSA won't feed pellets but the fuel feed light is on?
    • T
      Tiffany MartinezAug 14, 2025
      If your Breckwell stove isn't feeding pellets but the fuel feed light is on, there could be several reasons: * A blown fuse on the control board: replace it with a 5 Amp 250 Volt fuse. * The high limit switch has tripped: wait 30-45 minutes for the stove to cool. * A bad auger motor: remove the auger motor from the auger shaft and try to run the unit. * Auger jam: empty the hopper and remove the auger to clear any obstructions. * Loose wire or connector: check all wires and connectors connected to the auger motor and high limit switch. * Bad control board: test for power going to the auger motor.
  • A
    Amanda WalkerAug 19, 2025
    Why does the high limit switch keep tripping on my Breckwell Tradition P23FSA Stove?
    • P
      Patricia JohnsonAug 20, 2025
      The high limit switch on your Breckwell stove might be tripping due to several reasons. The convection blower may be overheating, so cleaning any dust off the windings and fan blades may help. Leaving the stove on the highest setting for extended periods can also cause this issue, as it's designed for short-term use. Using fuel other than wood pellets can also cause the high limit switch to trip. If none of these issues are present, the high limit switch itself may be malfunctioning and need replacement.
  • H
    haleygordonAug 25, 2025
    How to adjust air damper on Breckwell Tradition P23FSA Stove to stop glass from sooting up?
    • B
      Brad RamosAug 25, 2025
      To adjust the air damper on your Breckwell Stove to prevent the glass from sooting up, pull the damper knob farther out away from the side of the stove and try to burn the unit again. If the damper is broken, visually inspect the damper assembly to ensure the damper plate is attached to the damper rod.
  • C
    Christopher RodriguezAug 29, 2025
    What to do if changing pellets doesn't stop glass sooting up on my Breckwell Tradition P23FSA Stove?
    • D
      Denise MillerAug 29, 2025
      If changing pellets doesn't stop the glass from sooting up on your Breckwell Stove, other factors may be at play. Check if the stove or vent pipe is dirty, which restricts airflow through the burnpot. Ensure the vent pipe is installed correctly. Also, make sure the burnpot holes aren't blocked. Inspect the air intake pipe for blockages and test the combustion blower's RPM (should be around 3000 RPM after cleaning).
  • W
    williamsjamesSep 4, 2025
    What to do if Breckwell Stove high limit switch keeps tripping even after cleaning the blower?
    • D
      denise24Sep 4, 2025
      If the high limit switch on your Breckwell Stove continues to trip even after cleaning the blower, consider these factors: avoid using the highest heat setting for more than 1-2 hours, as it can lead to overheating. Ensure you're only using wood pellets as fuel. If these aren't the causes, the high limit switch itself might be faulty and need replacement.