1. Fill basin with sanitizing solution
2. Refit ice-cube slide (2 in Fig. 1) and flag support assembly (1 in Fig. 1)
Before connecting the appliance to the mains electricity supply, ensure that all cables and
electrical wiring are perfectly dry.
3. Operate ice maker for five one-minute periods, with a five-minute break between them
IMPORTANT: The pump must be in operation during sanitizing cycles (check that water is
sprayed). If it is not, immediately adjust timer regulation screw by turning it clockwise until the
indicator on the pin exits from the zone marked DEFROST.
Adjust the timer with a flat-head screwdriver (Fig. 2); remove right part of front panel if necessary.
4. Switch off machine and disconnect it from the mains electricity and water supply
5. Remove the appliance from its flush-mounting installation
6. Remove evaporator cover panel (Fig. 5)
7. Pour sanitizing solution onto top part of evaporator, distribute with a brush, and rinse thoroughly
with cold water
8. Open pump basin positioned on back of appliance, removing screws with a Phillips screwdriver
(Fig. 6)
9. Raise pump assembly, taking care not to damage wiring (Fig. 8)
10. Disconnect sprayer bank feed pipe from pump (7) and extract from hole (Fig. 9)
11. Remove (Fig. 1) and immerse in sanitizing solution for 30 minutes:
flag support assembly (1)
ice-cube slide (2)
overflow pipe (3)
sprayer bank (4) and side caps (5), after removing them from the bank
sprayer bank feed pipe (7)
pump filters (6)
evaporator cover panel (Fig. 5)
12. Wipe container walls and door, pump basin walls, immersed part of pump and bottom part of pump
basin lid with sanitizing solution using a sponge and brush (8 in Fig. 9)
13. Thoroughly rinse the parts mentioned in the preceding point with cold water
14. Thoroughly rinse ice-cube slide, evaporator cover panel, sprayer bank and the corresponding side
caps, flag support assembly, overflow pipe, pump filters and sprayer bank feed pipe under running
water
15. Thoroughly rinse pump basin with pressurised cold water
16. Refit pump assembly, securing it with screws
17. Secure pump wiring
18. Refit components previously removed
19. Reposition all panels, securing the top to rear panel with the screw
20. Refit the appliance in its flush-mounting installation
The ice-cube maker can now be reactivated as specified in the instruction manual.
IMPORTANT: All the ice produced during the first five cycles after cleaning and sanitizing
operations must be discarded.