INVERTER
SWIMMING POOL HEAT PUMP
USER MANUAL
Illustrative photo
i
Read the instructions
EN
VERZE 8. 6. 2017 / REVIZE: 3. 11. 2017

Questions and Answers

  • C
    Cynthia MoraAug 14, 2025
    Why does my Brilix Heat Pump show a high pressure error?
    • T
      Tammy CampbellAug 15, 2025
      A high pressure error in your Brilix Heat Pump can occur due to several reasons: * Too much refrigerant: In this case, drain the excess refrigerant. * High water or environment temperature: Clean the air heat exchanger. * Operating frequency too high: Check and reconnect the electrical cables from the high pressure switch and replace the high pressure switch. Additionally, ensure there are no gas leaks (contact a specialized company to add refrigerant if needed), clean the air heat exchanger, replace the filter, and check/reconnect the electrical cables from the low pressure switch, potentially replacing the low pressure switch.
  • J
    james00Aug 17, 2025
    What to do if my Brilix XHPFD 140 E Heat Pump has low pressure error?
    • O
      oliviafernandezAug 18, 2025
      If your Brilix Heat Pump displays a low pressure error, it could be due to: 1. Not enough refrigerant: Check for gas leaks and have a specialized company add refrigerant. 2. Insufficient flow: Clean the air heat exchanger. 3. Dirty filter: Replace the filter. 4. EEV failure. 5. Fan motor fault. 6. Low pressure switch failure: Check and reconnect the electrical cables from the low pressure switch, and if necessary, replace the low pressure switch.
  • B
    Bobby WilliamsAug 21, 2025
    What to do if my Brilix Heat Pump has impaired water flow?
    • N
      Noah MerrittAug 21, 2025
      If you are experiencing impaired water flow with your Brilix Heat Pump, it could be caused by: weak water flow, flow in the wrong direction, or flow switch failure. To resolve this: 1. Ensure the water flow is sufficient. 2. Make sure the water flow switch is connected correctly. 3. Check the wiring to the water flow switch. 4. Replace with a new water flow switch if necessary.
  • R
    Richard JohnsonAug 25, 2025
    How to fix sensor error inlet water temperature in Brilix Heat Pump?
    • S
      shane40Aug 25, 2025
      If your Brilix Heat Pump displays a sensor error for the inlet water temperature, it indicates that the sensor is either open or short circuited. To resolve this, check or replace the sensor.
  • T
    timothysavageAug 27, 2025
    How to fix sensor error outlet water temperature in Brilix Heat Pump?
    • N
      nichole01Aug 28, 2025
      If your Brilix Heat Pump displays a sensor error for the outlet water temperature, it means the sensor is either open or short circuited. You should check or replace the sensor.
  • D
    Daniel JohnsonAug 31, 2025
    How to fix sensor error heating condenser in Brilix XHPFD 140 E?
    • H
      hmillerAug 31, 2025
      If your Brilix Heat Pump shows a sensor error for the heating condenser, the sensor is likely open or short circuited. The suggested solution is to check or replace the sensor.
  • J
    James LindseySep 3, 2025
    How to fix sensor error gas return in Brilix XHPFD 140 E Heat Pump?
    • B
      bfranklinSep 3, 2025
      If your Brilix Heat Pump displays a sensor error related to gas return, it indicates that the sensor is either open or short-circuited. The solution is to check or replace the sensor.
  • A
    amy27Sep 6, 2025
    How to fix sensor error ambient temperature in Brilix XHPFD 140 E?
    • P
      patrickcomptonSep 7, 2025
      If your Brilix Heat Pump is showing a sensor error for the ambient temperature, this indicates the sensor is open or short circuited. You should check or replace the sensor.
  • B
    Brandon CoffeySep 10, 2025
    How to fix sensor error gas at the condenser output in Brilix XHPFD 140 E?
    • D
      David PetersonSep 12, 2025
      If your Brilix Heat Pump displays a sensor error for gas at the condenser output, it means the sensor is either open or short circuited. You should check or replace the sensor.

Summary

Specification

Dimension

Installation

Adjusting the bypass

Initial operation

Controller Operation

6.1 Power Button

Button to start, stop, and exit controller settings.

6.2 Mode Button

Mode button for operating functions with other buttons.

6.3 Display Lock & Temp Setting

Lock/unlock display and directly set water temperature.

6.4 Heating Indicator

Indicator light for heating operation and defrosting.

6.5 Cooling Indicator

Indicator light for cooling operation.

6.6 Auto Stop Indicator

Indicator light for automatic stop function.

6.7 Auto Start Indicator

Indicator light for automatic start function.

6.8 Parameter Checking

Procedure to check user parameters from d0 to d11.

Operation logic

7.1 Heating Operation Logic

Details working status, mode, and heat pump level for heating.

7.2 Cooling Operation Logic

Details working status, mode, and heat pump level for cooling.

Malfunction and Troubleshooting

8.1 Error Code Display

Lists faults, reasons, and solutions for error codes on LED controller.

8.2 Other Malfunctions and Solutions

Details malfunctions without LED display and their remedies.

Electrical Wiring

Maintenance

Exploded View

Brilix XHPFD 140 E Specifications

General IconGeneral
CategoryHeat Pump
ModelBrilix XHPFD 140 E
Heating Capacity14 kW
Energy Efficiency Ratio (EER)3.9
RefrigerantR410A
Noise Level52 dB(A)