A017 GB Issue 04
5
MAIN MENU – QUICK REFERENCE
TURNING ANGLE.
SETS THE ANGLE OF EGG TURNING
BY HOW LONG THE MOTOR RUNS.
RANGE 1 – 20 SECONDS.
DEFAULT 5 SECONDS.
TEMP
OK Å Æ
37.5C
OK - +
RH% 20
OK - +
HI 2.0C
INCUBATION TEMPERATURE.
RANGE 20.0 – 40.0°C (68.0 – 104.0°F).
DEFAULT 37.5°C (99.5°F).
RELATIVE HUMIDITY.
RANGE 20% – 80%.
DEFAULT 20%.
HIGH TEMPERATURE ALARM.
RANGE 1.0 – 5.0°C (1.8 – 9.0°F) ABOVE
SET INCUBATION TEMPERATURE.
DEFAULT 2.0°C
.
LOW TEMPERATURE ALARM.
RANGE 1.0 – 5.0°C (1.8 – 9.0°F) BELOW
SET INCUBATION TEMPERATURE.
DEFAULT 3.0°C
.
CELSIUS / FAHRENHEIT DISPLAY.
SWITCHES ALL TEMPERATURE
FIGURES BETWEEN °C AND °F.
DEFAULT °C.
SAVE.
ALL CHANGES ARE SAVED. RETURN
TO NORMAL OPERATION SCREEN.
CANCEL.
ALL CHANGES ARE IGNORED.
RETURN TO NORMAL OPERATION
SCREEN.
TURN 0/1
TURN 1
OK - +
MINS 45
OK - +
TURNING MODE.
SWITCHES THE TURNING SYSTEM
ON OR OFF.
DEFAULT ON (1).
TURNING INTERVAL.
SETS THE DELAY BETWEEN TURNS.
RANGE 5 – 180 MINUTES.
DEFAULT 45 MINUTES.
TURN ANG