24
EN
9 Technical Data
PURITY C lter system with lter cartridge
Operating pressure 2 bar to max. 8.6 bar
Water intake temperature 4 °C to 30 °C
Ambient
temperature during
operation 4 °C to 40 °C
storage/transport –20 °C to 50 °C
Water inlet and outlet connection G3/8” or John Guest 8 mm
Filter system
C25
Quell ST
C50
Quell ST
C150
Quell ST
C300
Quell ST
C500
Quell ST
C1100
Quell ST
Flow rate with 1 bar pressure loss 160 l/h 160 l/h 145 l/h 140 l/h 140 l/h 150 l/h
Nominal ow 30 l/h 60 l/h 60 l/h 60 l/h 100 l/h 100 l/h
Pressure loss at nominal ow 0.1 bar 0.25 bar 0.25 bar 0.25 bar 0.5 bar 0.5 bar
Empty lter cartridge volume 0.85 l 1 l 1.9 l 2.9 l 5.4 l 8.7 l
Weight
dry 0.8 kg 1.0 kg 1.8 kg 2.8 kg 4.6 kg 7.7 kg
wet 1.2 kg 1.6 kg 2.8 kg 4.2 kg 6.9 kg 12.5 kg
Dimensions
(Width/
Depth/
Height)
Filter system
(lter head with
lter cartridge)
119 mm/
108 mm/
219 mm
119 mm/
108 mm/
268 mm
117 mm/
104 mm/
419 mm
125 mm/
119 mm/
466 mm
144 mm/
144 mm/
557 mm
184 mm/
184 mm/
557 mm
Filter cartridge
108 mm/
108 mm/
210 mm
108 mm/
108 mm/
259 mm
104 mm/
104 mm/
410 mm
119 mm/
119 mm/
457 mm
144 mm/
144 mm/
548 mm
184 mm/
184 mm/
548 mm
Installed dimensions
(vertical installation with
wall mounting bracket)
137 mm/
130 mm/
219 mm
137 mm/
130 mm/
268 mm
137 mm/
128 mm/
419 mm
137 mm/
136 mm/
466 mm
144 mm/
148 mm/
557 mm
-
Operating position Horizontal or vertical