20
EN
If you decide not to return the lter cartridges, please dispose of all materials in accordance with
local regulations.
3 Operating and Safety Instructions
3.1 Qualied Personnel
Installation and maintenance of the lter system shall only be carried out by trained and authorised
personnel.
3.2 Correct Use
Perfect and safe operation of the product is subject to the installation, use and maintenance descri-
bed in this manual. Only use lter cartridges intended for use with your lter system.
3.3 Liability Exclusion
Installation and cartridge exchanges must be performed precisely in accordance with the instructions
in this manual. BRITA shall not be held liable for any damage, including subsequent damage, arising
from the incorrect installation or use of the product.
3.4 Specic Safety Information
• Water used as intake water for the PURITY C water lter system must be of drinking water
quality. The BRITA water lter system is only suitable for cold water use within the water
intake temperature range stated in Chapter 9.
• If there are ofcial instructions to boil tap water, the lter system must be decommissioned.
When the requirement to boil water comes to an end, the lter cartridge must be replaced
and the connections cleaned.
• It is generally recommended to boil tap water for certain groups of people (e.g. people
with weakened immune systems, babies). This also applies to ltered water.
• Note for people with kidney disease or dialysis patients: During the lter process the
potassium levels may increase slightly. If you suffer from kidney disease and/or have to
stick to a special potassium diet, we recommend you consult your doctor beforehand.
• The water ltrate is classied in Category 2 according to EN 1717.
• BRITA recommends not to decommission the lter system for long periods. If the BRITA
PURITY C lter system is not used for several days, we recommend that the lter system
be ushed with the volume of water indicated in the table below.
Filter cartridge Flushing volume after
2–3 days stagnation
Flushing volume after 4 weeks
stagnation
PURITY C25* 1.4 litres 14 litres
PURITY C50 2 litres 20 litres
PURITY C150 3 litres 30 litres
PURITY C300 6 litres 60 litres
PURITY C500 10 litres 100 litres
PURITY C1100 18 litres 180 litres
PURITY C1000 AC 1 litre 10 litres
PURITY C500 MinUp 0 litres 0 litres
*available only in Spain, France, Italy
• The lter system must not be opened or dismantled during operation. The lter cartridge must
not be opened.
• Production date
Production code – lter head – example: H 9375 01381
9 Production year, this example: 2019
37 Production week, this example: calendar week 37
5 Production day from Monday (1) to Friday (5); this example: Friday
01381 Serial identication number