26
EN
PURITY C lter system with lter cartridge
Operating pressure 2 bar to max. 8.6 bar
Water intake temperature 4 °C to 30 °C
Ambient
temperature during
operation 4 °C to 40 °C
storage/transport –20 °C to 50 °C
Water inlet and outlet connection G3/8” or John Guest 8 mm
Filter system C50 Fresh C1000 AC C500 MinUp
Flow rate with 1 bar pressure loss 160 l/h 140 l/h -
Nominal ow 60 l/h 30–180 l/h* 20 l/h
Pressure loss at nominal ow 0.25 bar 0.2–1.4 bar* 0.1 bar
Empty lter cartridge volume 1 l 0.23 l 5.4 l
Weight
dry 0.8 kg 0.5 kg 7.6 kg
wet 1.7 kg 1.0 kg 10.1 kg
Dimensions
(Width/
Depth/
Height)
Filter system
(lter head with
lter cartridge)
119 mm/
108 mm/
268 mm
109 mm/
93 mm/
238 mm
144 mm/
144 mm/
557 mm
Filter cartridge
108 mm/
108 mm/
259 mm
88 mm/
88 mm/
231 mm
144 mm/
144 mm/
548 mm
Installed dimensions
(vertical installation with
wall mounting bracket)
137 mm/
130 mm/
268 mm
137 mm/
120 mm/
238 mm
144 mm/
148 mm/
557 mm
Operating position Horizontal or vertical Vertikal
Nominal capacity - 10,000 l -
Chlorine reduction DIN EN 14898 - > 90 % -
Chlorine reduction NSF 42 - Class I (50 %) -
Particle retention NSF 42 - Class I (0.5 μm) -
* Working ow range and associated pressure loss: 30–180 l/hr/0.2–1.4 bar