7
PURITY C Steam
The bypass position can be adjusted to the local water quality or the machine type. The
following recommendations for bypass settings apply by default:
Position 0: All devices in areas with an extremely high water hardness level (CH ≥ 22 °dH)
Position 1: Combi ovens and conventional ovens with direct injection system
Position 2: Combi ovens and conventional ovens with boiler system
Position 3: All devices in soft water areas (CH ≤ 7 °dH)
You can obtain individual recommendations from your BRITA contact.
Operation of lter only with PURITY C Steam lter head.
PURITY C Steam - Filter capacity in litre
°dH
(Carbonate hard-
ness)
PURITY C500 Steam PURITY C1100 Steam
Bypass setting Bypass setting
0 1/2 3 0 1/2 3
4 7083 7792 8677 11980 13178 14676
5 7083 7792 8677 11980 13178 14676
6 7083 7792 8677 11980 13178 14496
7 6071 6679 7438 10269 11295 12425
8 5313 5844 6508 8985 9884 10872
9 4722 5194 5785 7987 8785 9664
10 4250 4675 5206 7188 7907 8697
11 3864 4250 4733 6535 7188 7907
12 3542 3896 4339 5990 6589 7248
13 3269 3596 4005 5529 6082 6690
14 3036 3339 3719 5134 5648 6212
15 2833 3117 3471 4792 5271 5798
16 2656 2922 3254 4493 4942 5436
17 2500 2750 3063 4228 4651 5116
18 2361 2597 2892 3993 4393 4832
19 2237 2461 2740 3783 4161 4578
20 2125 2338 2603 3594 3953 4349
21 2024 2226 2479 3423 3765 4142
22 1932 2125 2366 3267 3594 3953
23 1848 2033 2264 3125 3438 3782
24 1771 1948 2169 2995 3295 3624
25 1700 1870 2083 2875 3163 3479
26 1635 1798 2002 2765 3041 3345
27 1574 1731 1928 2662 2928 3221
28 1518 1670 1859 2567 2824 3106
29 1466 1612 1795 2479 2726 2999
30 1417 1558 1735 2396 2636 2899
31 1371 1508 1679 2319 2551 2806
32 1328 1461 1627 2246 2471 2718
33 1288 1417 1578 2178 2396 2636
34 1250 1375 1531 2114 2326 2558
35 1214 1336 1488 2054 2259 2485