WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guidelines and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. The wiring must be permanent. DO NOT USE AN EXTENSION
CORD! Use 14 GA. MINIMUM copper wire. Although the Powered
Attic Ventilator may be wired directly to power, we advise that
some type of shut off switch be installed in the line. Please see
the section on electrical wiring for suggested wiring diagrams
and instructions.
7. To reduce the risk of electric shock, do not use this fan with
any solid-state speed control device.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. This unit has an unguarded impeller. Do not use in locations
readily accessible to people or animals.
4. Fan is equipped with a thermostat which may start fan
automatically. To reduce risk of injury or electric shock while
servicing or cleaning unit, switch power off at service panel
and lock service panel to prevent power from being switched
on accidentally. When the service disconnecting means cannot
be locked, securely fasten a prominent warning device, such
as a tag, to the service panel.
5. Home Ventilating Institute (HVI) recommends one square foot
of open air inlet per 300 cfm of fan capacity. The best location
for these air intake vents are under the eaves with direct access
to the attic. Failure to provide these intakes could cause natural-
draft gas appliances to backdraft.
6. Your attic fan installation will create a screened opening into
your attic space. During a heavy rain storm there could be a
light spray of rain into this attic space. This is a normal condition
with all attic ventilators and will not cause any damage to the
structure. We recommend that you do not store any valuable
articles directly under the fan opening in the roof. During extreme
rain and wind storms you may want to turn on your attic ventilator
to prevent excess moisture accumulation in your attic.
7. Records show, under ideal conditions, exposed galvanized steel
can remain rust free up to 100 years. For best protection, the
exposed portion of the roof sheet should be painted, especially
in areas of unusually high industrial air pollution. Follow paint
manufacturer's instructions for good adhesion.
8. This ventilator is intended for roof installation. The Broan Model
353 Gable Mount Ventilator is available for side wall applications.
9. The dome may be painted with a high-quality paint. Follow the
paint manufacturer's recommendations for powder-coated steel.
10. Please read specification label on product for further information
and requirements.
ROOF-MOUNT
POWERED ATTIC VENTILATOR
READ AND SAVE THESE INSTRUCTIONS
q
Slotted Screwdriver
q
Drill
q
1/4" Drill Bit
q
Sabre Saw or Keyhole Saw
q
Hammer
q
Ruler
q
Pencil
q
Utility Knife
q
Pry Bar (to remove roofing nails)
q
Roofing Cement
q
Galvanized Roofing Nails (1¾" min.)
q
Electrical Supplies (to comply with codes)
TOOLS AND MATERIALS REQUIRED

Other manuals for Broan 349BR

Question and Answer IconNeed help?

Do you have a question about the Broan 349BR and is the answer not in the manual?

Summary

Safety and Instructions

General Safety Warnings

Critical safety instructions to reduce fire, electric shock, or injury risks.

Operational Precautions

Precautions for general use, motor protection, and ventilation requirements.

Installation Procedure

Ventilator Location

Locate the ventilator at the center of the rear slope, high on the roof.

Roof Opening Preparation

Marking and drilling a guide hole, then cutting the roof opening with a template.

Cutting Shingles and Boards

Cut out shingles and roof boards inside the marked circles.

Installing Flashing

Slide flashing under shingles and center the ventilator over the hole.

Securing and Sealing

Nail flashing securely and seal openings with roofing cement.

Wiring and Thermostat Adjustment

Wiring Instructions

Connect fan motor, house cable, and ground according to electrical codes.

Thermostat Adjustment

Adjust the fan's start temperature from 60°F to 120°F.

Service Parts and Warranty

Service Parts Identification

List of key numbers, part numbers, and descriptions for replacement parts.

Product Warranty Information

Details on the one-year limited warranty, coverage, and service procedures.

Broan 349BR Specifications

General IconGeneral
BrandBroan
Model349BR
CategoryFan
LanguageEnglish

Related product manuals