EasyManua.ls Logo

Broan 751 - User Manual

Broan 751
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Page 1
MODEL 751
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a promi-
nent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI
(Ground Fault Circuit Interrupter) - protected branch circuit.
8. Never place a switch where it can be reached from a tub or
shower.
9. To reduce the risk of electrical shock, do not use this fan with
any solid-state speed control.
10. Not for use in kitchens.
11. Do not install in a ceiling insulated to a value greater than R-40.
12. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further informa-
tion and requirements.
FAN / LIGHT
COMBINATION VENTILATOR
READ AND SAVE THESE INSTRUCTIONS
FOR BEST RESULTS
When installing the Exhaust Fan/Light in a new construction site,
install housing during the rough-in construction of the building.
The blower unit, reflector and grille should be installed after the
finished ceiling is in place.
PLANNING DUCTWORK AND WIRING
DUCTWORK
1. Use 4" round duct.
2. Plan duct run from discharge opening of fan to the outside. For
best fan performance, make duct run as short as possible and
use minimum number of elbows.
3. Use optional Broan ducting accessories as needed.
WIRING
Plan to run 120 VAC house wiring (with ground) from power source,
through wall switch, to junction box in housing. For separate con-
trol of fan and light use an optional Broan switch.
IMPORTANT: Use wire suitable for 90
o
C.
Question and Answer IconNeed help?

Do you have a question about the Broan 751 and is the answer not in the manual?

Summary

READ AND SAVE THESE INSTRUCTIONS

WARNING: Safety Instructions

Critical safety warnings to reduce risk of fire, electric shock, or injury, covering electrical, installation, and usage precautions.

CAUTION AND BEST RESULTS

Important precautions for general ventilation and motor protection, plus tips for optimal installation.

PLANNING DUCTWORK AND WIRING

Planning steps for ductwork (size, routing) and electrical wiring (power, switches).

INSTALLATION IN A NEW CONSTRUCTION SITE

PREPARATION AND HOUSING MOUNTING

Steps to prepare the unit, mount the housing using tabs or hanger bars, and attach duct collar.

WIRING CONNECTIONS

Connecting the electrical wiring, including ground, neutral, and hot wires, to the fan.

POWER;BLOWER UNIT AND COMPLETING INSTALLATION

INSTALLATION IN EXISTING CONSTRUCTION: PLANNING AND PREPARATION

Planning for existing construction, including location, checks, and initial prep like removing unit.

INSTALLATION IN EXISTING CONSTRUCTION: MOUNTING AND CONNECTIONS

Step-by-step mounting, cutting, cleat installation, and connecting ductwork and wiring.

USE AND CARE

RELAMPING AND CLEANING PROCEDURES

Procedures for replacing the lamp and cleaning the unit's grille and lens assembly.

MOTOR LUBRICATION, SERVICE PARTS, AND WARRANTY

Information on motor lubrication, ordering replacement parts, and details of the manufacturer's limited warranty.

Broan 751 Specifications

General IconGeneral
CFM70
Air Flow70 CFM
Voltage120 V
Housing MaterialGalvanized Steel
Mounting TypeCeiling Mount
TypeCeiling
Motor TypePermanently Lubricated

Related product manuals