EasyManua.ls Logo

Broan CJD3 Series - User Manual

Broan CJD3 Series
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Page 1
CJD3 SERIES
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have
questions, contact the manufacturer at the address or telephone number
listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and
lock the service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means cannot
be locked, securely fasten a prominent warning device, such as a tag, to
the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards, includ-
ing fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent backdraft-
ing. Follow the heating equipment manufacturer’s guideline and safety
standards such as those published by the National Fire Protection As-
sociation (NFPA), and the American Society of Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
6. To reduce the risk of fire or electric shock, do not use this range hood
with an additional speed control device.
7. Ducted fans must always be vented to the outdoors.
8. To reduce the risk of fire, use only metal ductwork.
9. Use with approved cord-connection kit only.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers cause
smoking and greasy spillovers that may ignite. Heat oils slowly on low or
medium settings.
2. Always turn hood ON when cooking at high heat or when cooking flaming
foods.
3. Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the size of
the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A
RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray,
then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the
flames do not go out immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent steam
explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already know
how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CJD3 SERIES
RANGE HOOD
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with
the homeowner.
Homeowner: Operating and
Cleaning information on page 6.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
4. A maximum height of 30” from the top of the hood to the cooktop is rec-
ommended for best capture of cooking impurities. The top of the hood
MUST NOT BE LESS than 24” above the cooktop.
5. Please read specification label on product for further information and
requirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
“PREPARE HOOD LOCATION”
Run ductwork from roof or wall cap, and electrical wiring from service
panel - to installation location
“PREPARE THE HOOD”
Get your hood ready for installation
“CONNECT WIRING”
Make electrical wiring connections to hood
“INSTALL HOOD”
Secure hood to cabinet and ductwork - install bulbs and filters
“OPERATION”
How to use the hood controls
“CLEANING”
Keep your hood in top working condition
“SERVICE PARTS”
Part numbers and exploded view of hood components
“WARRANTY”
One-year limited warranty and how to contact us
NOTE If hood is to be installed Non-Ducted:
Purchase a set of (2) non-ducted filters from your
local distributor or retailer and attach them to the
aluminum mesh filters.
Patent No.:
US D450, 829 S
!
FOR DOMESTIC COOKING ONLY
!
Register your product online at: www.broan.com/register
Question and Answer IconNeed help?

Do you have a question about the Broan CJD3 Series and is the answer not in the manual?

Summary

Safety and General Information

General Safety Warnings

Key safety instructions to prevent fire, electric shock, or injury during use and installation.

Cooking Fire Safety

Guidelines to reduce the risk of a range top grease fire and actions to take.

Cautionary Notes

Important cautions for indoor use, ventilation, and installation specifics like height.

Prepare Hood Location

Ducting and Cutout Planning

Determine ducting type (vertical/horizontal) and plan cutouts for installation.

Mounting Screw Locations

Specifies mounting screw positions for different hood sizes and ducting types.

Prepare Hood Components

Remove Bottom Cover and Light Panel

Steps to remove the Teflon-coated bottom cover and light panel for access.

Remove Damper;Duct Connector

Instructions to remove the damper/duct connector from the hood interior.

Prepare Air Chute and Baffle

Steps for removing and re-installing the air chute and baffle for proper airflow.

Duct Knockout and Blower Wheel Setup

Remove Duct Knockouts

Remove the appropriate duct knockout for vertical or horizontal discharge.

Install Damper;Duct Connector

Attach the damper/duct connector to the hood for ducted installations.

Non-Ducted Blower Wheel Modification

Instructions for attaching a performance ring to the blower wheel for non-ducted use.

Wiring and Hood Installation

Connect House Wiring

Steps for safely connecting the 120 VAC house wiring to the hood.

Mount and Connect Ductwork

Hang the hood, secure it with mounting screws, and connect the ductwork.

Hood Operation and Maintenance

Non-Ducted Filter Installation

Guidance on purchasing and attaching non-ducted filters for specific models.

Using Hood Controls

Instructions for operating fan, light, and delay off features via touch controls.

Heat Sentry and Cleaning

Details on automatic fan speed adjustment and procedures for cleaning.

Service Parts and Diagrams

Replacement Parts List

Detailed list of part numbers and descriptions for replacement components with a diagram.

Warranty Information

Limited Warranty Terms

Coverage period, exclusions, limitations, and how to obtain warranty service.

Broan CJD3 Series Specifications

General IconGeneral
Power SourceHardwired
MaterialStainless Steel
Width30 in.
Filter TypeAluminum Mesh
Venting OptionsDucted