EasyManua.ls Logo

Broan HRV200H - User Manual

Broan HRV200H
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
User Manual
VENTILATION SYSTEMS
VB0065
vänEE Canadian Model Numbers
1001 ERV
1001 HRV*
2001 ERV
2001 HRV*
Broan U.S.A. Model Numbers
HRV100H
HRV200H
ERV100HC
ERV200HC
* These products earned the ENERGY STAR® by meeting strict
energy efficiency guidelines set by Natural Resources Canada
and the US EPA. They meet ENERGY STAR requirements only
when used in Canada.
03118 rev. 08
Address of your installer
To register your Broan product on line visit: www.broan.com/register

Other manuals for Broan HRV200H

Questions and Answers

Summary

About This Manual;Product

Safety Warnings and Precautions

Highlights critical safety instructions, potential hazards, and operational precautions for user safety and equipment protection.

Replacement Parts and Repairs

Emphasizes using genuine manufacturer parts and seeking professional service for optimal performance and safety.

Your Unit and Its Purpose

Unit Description and Components

Details the main components of the ventilation unit, including power cord, filters, core, tray, and blower assembly.

Purpose of the Ventilation System

Explains the function of the ventilation system in providing fresh air and exhausting stale, humid air to maintain indoor air quality.

Recovery Features

Heat Recovery Core Functionality

Describes how units with a polypropylene core recover heat from exhaust air to warm incoming fresh air without mixing.

Heat and Humidity Recovery Core

Explains the function of an enthalpic core for reducing ventilation costs by transferring heat and humidity between air streams.

Defrosting Operation

Defrosting Cycle Explanation

Details the unit's defrost cycle operation when outside temperatures drop below freezing to prevent frost buildup in the core.

Technical Specifications

Model Specifications and Data

Provides technical specifications for different ventilation unit models, including dimensions, weight, and power consumption.

Operating the Unit with Controls

Control Device Overview and Instructions

Introduces various control devices for the ventilation unit and directs users to specific pages for operation instructions.

Platinum Main Control Operation

Instructions for operating the Platinum main control panel for ventilation and recirculation modes.

Deco-Touch Main Control Operation

Guide to using the Deco-Touch main control for managing ventilation modes like OFF, RECIRC, MIN, and MAX.

VT1 W Main Control Operation

Explains how to operate the VT1W main control for adjusting air supply and condensation settings.

VT2 W Main Control Operation

Details the operation of the VT2W main control, including air supply and condensation adjustments.

Control Device Details (Continued)

Dehumidistat Control Usage

Instructions for using the Dehumidistat control to manage indoor humidity levels during different seasons.

3-Position Switch Functionality

Information on operating the 3-position switch for adjusting air supply speed on specific HRV models.

Optional Control Timers

Guide to using 20-min, 20/40/60-min push-button timers, and 60-minute crank timer for timed ventilation.

Platinum Main Control: Screen and Casing

On-Screen Indicator Meanings

Explains the various indicators and symbols displayed on the Platinum control screen for ventilation status and settings.

Casing Indicators and Keys

Details the physical indicators (power, filter maintenance) and function keys (SMART, SET, arrows, MODE/PREF, Reset) on the Platinum control unit.

Platinum Main Control: Setting Preferences

Setting Control Preferences

Guides users through setting preferences like current day, time, temperature units, and backlight options on the Platinum control.

Navigating Control Settings

Provides step-by-step instructions for navigating and selecting values for various settings on the Platinum control.

Platinum Main Control: Program Mode Setup

Setting Daily Periods for Program Mode

Explains how to customize the ventilation unit's operation by setting daily periods, starting hours, and ventilation speeds.

Deco-Touch Main Control: Operation

Backlight Functionality

Describes how the backlight on the Deco-Touch control activates and deactivates upon button presses.

Understanding Operating Modes

Details the different operating modes of the Deco-Touch control: OFF, RECIRC, 20 MIN/H, MIN, and MAX.

Platinum Main Control: Humidity and Standby Settings

Setting Relative Humidity and Standby Modes

Guides users on setting desired indoor humidity levels and selecting standby modes (OFF or RECIRCULATION).

Platinum Main Control: Advanced Features

Dehumidistat Override Function

Explains how to use the dehumidistat override for high-speed exchange to manage indoor humidity, especially in non-heating seasons.

Maintenance Indicator and Reset

Describes the maintenance indicator on the control and how to reset it after performing maintenance.

VT1 W Main Control: Air Supply and Condensation

Adjusting Air Supply Control

Instructions on selecting air supply speeds (MIN, MAX) and turning the unit OFF using the VT1W control.

Adjusting Condensation Control

Guides on setting the condensation control for summer and winter/spring months to manage window condensation.

VT2 W Main Control: Air Supply and Condensation

Adjusting Air Supply Control

Details on adjusting air supply (MIN, MAX, INTERMITTENT) and turning off the unit using the VT2W control.

Adjusting Condensation Control

Explains how to adjust the condensation control on the VT2W for summer and winter/spring to manage humidity.

VT2 W Main Control: Indicators

Understanding Light Indicators

Explains the meaning of the light indicators on the VT2W control related to humidity, operation, and maintenance.

Dehumidistat Main Control Operation

Dehumidistat Control Usage

Instructions for adjusting the Dehumidistat control to set desired indoor humidity levels for fall/winter/spring and summer.

3-Position Switch Operation

3-Position Switch Functionality

Details on how to operate the 3-position switch for daily air supply adjustment and turning the unit off on specific models.

Optional Controls Usage

20-Minute Push-Button Timer

Instructions for using the 20-minute push-button timer for temporary high-speed air exchange.

20;40;60-Minute Push-Button Timer

Guide to operating the multi-minute push-button timer for timed air exchange sessions.

60-Minute Crank Timer

Details on how to activate and set the duration for the 60-minute crank timer.

Maintenance Procedures

Quarterly Maintenance (Every Three Months)

Provides step-by-step instructions for performing quarterly maintenance, including cleaning filters and checking components.

Quarterly Maintenance: Specific Tasks

Cleaning Condensation Tray and Air Intake

Instructions for cleaning the condensation tray and inspecting the exterior air intake hood for obstructions.

Annual Maintenance (Fall)

Annual Recovery Core Cleaning

Outlines the annual maintenance procedures, including cleaning the recovery core for both heat and heat/humidity recovery units.

Annual Maintenance: Fan Wheels

Cleaning Centrifugal Fan Wheels

Step-by-step guide to cleaning the centrifugal fan wheels, including disassembly and reassembly of the blower assembly.

Troubleshooting Common Issues

No Outside Temperature Display

Troubleshooting steps for when the outside temperature is not shown on the Platinum wall control display.

Error Codes E1 or E3

Instructions to contact the installer if error codes E1 or E3 appear on the Platinum or Deco-Touch wall controls.

Unit Not Working or Flashing Indicators

Steps to check power, reset the unit, and contact installer for non-operational units or flashing indicators.

Noisy Unit and Condensation Issues

Troubleshooting tips for noisy units, excessive humidity, and window condensation, including control adjustments.

Dry Air or Cold Supply Air

Advice for addressing dry indoor air or cold supply air, including control adjustments and system checks.

Broan HRV200H Specifications

General IconGeneral
TypeHeat Recovery Ventilator
Airflow Capacity200 CFM
Airflow @ 0.2 in. w.g.200 CFM
Voltage120 V
Frequency60 Hz
Motor TypePSC
Defrost ControlAutomatic
Housing MaterialGalvanized Steel
Duct Size6 in
Core TypeCrossflow

Related product manuals