1
OPTION - To mount housing anywhere between ceiling framing:
Use optional Hanger Bar Kit (sold separately from local distributors
or website). Follow mounting instructions included with kit.
ROOF CAP* (with built-in damper)
WALL CAP*
(with built-in
damper)
4-IN. ROUND
ELBOWS*
FAN
HOUSING
Seal gaps
around
housing.
Seal duct joints
with tape.
INSULATION
(Place around and
over fan housing.)
POWER
CABLE *
* Purchase separately.
OR
Keep duct
runs short.
4-IN. ROUND
DUCT*
IMPORTANT -
The ducting from this fan to the outside of the building
has a strong effect on the air flow, noise and energy use of the fan. Use
the shortest, straightest duct routing possible for best performance, and
avoid installing the fan with smaller ducts than recommended. Insulation
around the ducts can reduce energy loss and inhibit mold growth. Fans
installed with existing ducts may not achieve their rated airflow.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI
(Ground Fault Circuit Interrupter) - protected branch circuit (ceiling
installation only).
8. This unit must be grounded.
READ AND SAVE THESE INSTRUCTIONS
Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45
o
45
o
NOT FOR USE IN
A COOKING AREA.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. This product can be installed in a wall if mounted 8-ft. or more
above the floor.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further information
and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance
- lower or remove grille and vacuum interior of unit with the dusting
brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace the
blower assembly (includes motor and impeller).
OPERATION
The fan and light can be operated separately. Use a 2-function wall
control.
Flex
TM
Series Fan/Light ONLY: Do not use a speed control to
operate the fan.
For Warranty Statement, Service Parts, Technical Support, or to
Register your product, please visit our website or call:
In the United States - Broan.com 800-637-1453 or NuTone.com
888-336-6151. In Canada - Broan.ca or NuTone.ca 877-896-1119
Roomside / Flex
TM
Series Fan/Light
Question and Answer IconNeed help?

Do you have a question about the Broan Roomside / Flex Series and is the answer not in the manual?

Summary

Safety Warnings

Safety Cautions

Cleaning and Maintenance

Operation

All Installations

Remove Packing and Blower

Remove all packing material and unplug the blower from the fan housing.

Remove Wiring Panel

Remove the wiring panel from the fan housing.

Select CFM

For some models, select the CFM based on room size and desired airflow.

Attach Flanges

For some models, attach flanges to the housing if desired or required.

New Installation

Attach Damper;Duct Connector

Push the connector through the housing opening and secure it with a screw.

Mount Housing to Ceiling Structure

Mount the housing flush with the finished ceiling, securing it with fasteners.

Retrofit Installation

Remove Old Fan and Prepare Ceiling

Enlarge ceiling opening as necessary and remove the old fan housing and attachments.

Fold Mounting Ears

Fold the mounting ears flat against the housing.

Connect Wiring

Connect the power cable and house wiring to the fan wiring using approved connectors.

Mount Fan to Ceiling Structure

Mount the fan housing to the ceiling structure using appropriate fasteners.

All Installations - Ducting and Blower

Connect 4-in. Round Duct

Pull ducting through the opening, tape it to the connector, and secure it.

Install Blower

Re-install the blower and plug it into the receptacle or controller module.

Install Grille

Broan Roomside / Flex Series Specifications