OPTION - To mount housing anywhere between ceiling framing:
Use optional Hanger Bar Kit (sold separately from local distributors
or website). Follow mounting instructions included with kit.
ROOF CAP* (with built-in damper)
WALL CAP*
(with built-in
damper)
4-IN. ROUND
ELBOWS*
FAN
HOUSING
Seal gaps
around
housing.
Seal duct joints
with tape.
INSULATION
(Place around and
over fan housing.)
POWER
CABLE *
* Purchase separately.
OR
Keep duct
runs short.
4-IN. ROUND
DUCT*
IMPORTANT -
The ducting from this fan to the outside of the building
has a strong effect on the air flow, noise and energy use of the fan. Use
the shortest, straightest duct routing possible for best performance, and
avoid installing the fan with smaller ducts than recommended. Insulation
around the ducts can reduce energy loss and inhibit mold growth. Fans
installed with existing ducts may not achieve their rated airflow.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI
(Ground Fault Circuit Interrupter) - protected branch circuit (ceiling
installation only).
8. This unit must be grounded.
READ AND SAVE THESE INSTRUCTIONS
Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45
o
45
o
NOT FOR USE IN
A COOKING AREA.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. This product can be installed in a wall if mounted 8-ft. or more
above the floor.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further information
and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance
- lower or remove grille and vacuum interior of unit with the dusting
brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace the
blower assembly (includes motor and impeller).
OPERATION
The fan and light can be operated separately. Use a 2-function wall
control.
Flex
TM
Series Fan/Light ONLY: Do not use a speed control to
operate the fan.
For Warranty Statement, Service Parts, Technical Support, or to
Register your product, please visit our website or call:
In the United States - Broan.com 800-637-1453 or NuTone.com
888-336-6151. In Canada - Broan.ca or NuTone.ca 877-896-1119
Roomside / Flex
TM
Series Fan/Light
Question and Answer IconNeed help?

Do you have a question about the Broan Roomside Series and is the answer not in the manual?

Summary

General Safety Instructions

Warning: Reduce Risk of Fire, Shock, or Injury

Safety guidelines for installation and use, focusing on electrical hazards, fire prevention, and personal injury.

Caution: Ventilation and Material Handling

Precautions for general ventilation use, avoiding hazardous materials, and protecting motor components.

Cleaning and Maintenance

Cleaning Procedures

Instructions for cleaning the fan grille and interior using a dusting brush attachment.

Motor Lubrication and Noise

Notes that the motor is permanently lubricated and how to address bearing noises by replacing the blower assembly.

Operation Guidelines

Separate Fan and Light Control

Describes operating the fan and light independently using a 2-function wall control.

Speed Control Restriction

Advises against using a speed control device with the Flex™™ Series Fan/Light.

Installation Steps

Initial Preparation for All Installations

Steps for removing packing, blower, and wiring panel, and selecting CFM settings.

New Installation: Duct and Housing

Attaching the duct connector to the housing and mounting the housing securely to the ceiling structure.

Retrofit Installation: Removal and Wiring

Removing existing fan, preparing ceiling, and connecting house wiring to the fan.

Retrofit Installation: Mounting

Folding mounting ears and mounting the fan housing to the ceiling structure.

Final Connections and Grille Installation

Connecting ductwork, installing the blower, and attaching the grille with light module.