Version4.0 EUROPE
TUNGSTEN SMARTHEAT™
GAS HEATER
BY BROMIC
INSTALLATION, INSTRUCTION AND
SERVICE MANUAL
SUITABLE FOR GAS RADIANT HEATER MODELS:
TUNGSTEN 300 BURNER AND TUNGSTEN 500  BURNER
!
!
DANGER
If you smell gas:
1. Shut o gas to the appliance
2. Extinguish any open ame
3. If odour continues, keep away from the
appliance and immediately call your gas
supplier or re department.
WARNING: For Outdoor Use Only.
This appliance shall not be installed or
used indoors.
!
Do not stor
e or use petrol or other amable vapor
and liquids in the vicinity of this or any other
appliance.
An LP-cylinder not connected for use shall not be
stored in the vicinity of this or any other appliance.
WARNING
WARNING: I
mproper installation,
adjustment, alteration, service or maintenance
can cause property damage, injury or death.
Read the installation, operating and
maintenance instructions thoroughly before
installing or servicing this equipment.
!
WARNING: Improper installation,
adjustment, alteration, service or maintenance
can cause property damage, injury or death.
Read the installation, operating and
maintenance instructions thoroughly before
installing or servicing this equipment.
!

Questions and Answers

  • J
    juliesmithAug 13, 2025
    Why does my Bromic Heating TUNGSTEN 300-BURNER smell like gas?
    • K
      Kenneth RussellAug 14, 2025
      If you notice a gas odor coming from your Bromic Heating Gas Heater, it could be due to several reasons. Check all pipe connections with a soap solution and tighten any loose connections. If the odor persists, the regulator, manual shut-off valve, or gas control valve might be defective and require replacement. Also, ensure the flexible hose is tightened.
  • J
    Jeffrey MoranAug 17, 2025
    How to fix a Bromic Heating Gas Heater that will not turn on?
    • E
      Erin HendersonAug 17, 2025
      If your Bromic Heating Gas Heater won't turn on, there could be a few potential causes. First, have an authorized electrician check the power supply. Second, have an authorized gas fitter check the gas supply. Finally, the control module may be in Lock-out mode; in that case, reset the Honeywell Lock-out.
  • D
    Devon SnyderAug 21, 2025
    Why does my Bromic Heating TUNGSTEN 300-BURNER Gas Heater turn on and off?
    • T
      Tricia HebertAug 21, 2025
      If your Bromic Heating Gas Heater turns on but then cycles on and off, it could be due to a few reasons. The flame on the ionization rod may be insufficient, so check and set the gas pressure and clear any obstruction to the burner venturi and injectors. Drafty conditions can also cause this issue, so discontinue use in high winds. Lastly, an insufficient earth connection between the heater and control box could be the problem; replace the wiring harness and clean connections to ensure a good earth.
  • N
    Nicole SpencerAug 25, 2025
    What to do if there is carbon formation on my Bromic Heating TUNGSTEN 300-BURNER Gas Heater?
    • M
      Mary SmithAug 25, 2025
      If you observe carbon formation on the ceramic tile surface of your Bromic Heating Gas Heater's burner, it could be due to several factors. The orifice might be misaligned, so consult your sales agent or the factory. There could be an obstruction in the venturi tube, so clean it with a bottle brush. Low gas pressure could also be the cause, so provide the required pressure. Finally, ensure the correct type of gas is supplied to the heater by checking the label.
  • I
    icruzAug 28, 2025
    What to do if my Bromic Heating TUNGSTEN 300-BURNER has no gas?
    • C
      Christopher HaynesAug 29, 2025
      If there is no gas supply to your Bromic Heating Gas Heater, it could be due to several reasons. There might be air in the gas line, so purge the line. The manual shut-off valve may be closed, so open the valve. The regulator might be sticking, in which case, replace it. Alternatively, the regulator could be reversed, so remove it and install it properly.
  • R
    Ryan BowersSep 1, 2025
    Why is my Bromic Heating TUNGSTEN 300-BURNER Gas Heater burning gas inside the burner casting?
    • G
      Garrett SmithSep 1, 2025
      If the gas/air mixture is burning inside the burner casting of your Bromic Heating Gas Heater (flashback), it may be because of separation or cracks in the ceramic tiles, in which case, replace the burner assembly. The heater might also be mounted at an incorrect angle, so check the angle of the heater against the nameplate. Excessive drafts can also cause this, so shield or relocate the heater.
  • J
    james79Sep 5, 2025
    Why is the ceramic tile surface temperature low on my Bromic Heating TUNGSTEN 300-BURNER?
    • A
      Alexander ValenciaSep 5, 2025
      If your Bromic Heating Gas Heater has a low ceramic tile surface temperature, it could be due to several reasons. Low manifold gas pressure could be the cause. Low gas inlet pressure can also cause this issue, so clean the orifice. If the orifice is partially blocked with foreign matter, provide adequate ventilation of by-products. A misaligned manifold due to excessive torque on the pipe during installation can also cause this; replace the manifold. If the gas supply piping is too small, increase the gas pressure or replace the piping. Finally, remove any foreign matter in the venturi tube with a bottle brush.
  • S
    sharonwrightSep 8, 2025
    Why is the control assembly of my Bromic Heating TUNGSTEN 300-BURNER overheating?
    • K
      Kimberly ColeSep 9, 2025
      If the control assembly of your Bromic Heating Gas Heater is overheating, ensure the heater is mounted correctly. Mount the wall bracket/control housing against a vertical flat surface, following the instructions in the installation section of this manual. Always use supplied parts to mount the heater.

Summary

Product Overview

Specifications

Details technical specifications for Tungsten Smart-Heat 300 and 500 models.

For Installation and Use in Outdoor or Amply Ventilated Areas

Gas Requirements

Details the gas type and inlet pressure requirements for the heaters.

Installation Instructions

Heater Installation Instructions

Details the step-by-step process for installing the heater unit.

Commissioning Instruction

Check Gas Pressure

Verifies and adjusts the gas pressure for correct appliance operation.

Operating Instructions

Maintenance and Servicing

Operation Data - Honeywell Control Box

Operation Data - Honeywell Valve

Wiring Diagram - Honeywell Control, Honeywell Gas Valve

Troubleshooting

Bromic Heating TUNGSTEN 300-BURNER Specifications

General IconGeneral
ModelTUNGSTEN 300-BURNER
BrandBromic Heating
CategoryGas Heater
MaterialStainless Steel
Burner MaterialCeramic
ApplicationOutdoor
Fuel TypeNatural Gas / Propane
Gas Connection1/2" BSP
Warranty1 Year

Related product manuals