Accuracy | ±1% of full scale |
Repeatability | 0.25% of full scale |
Pressure Rating | 150 psig |
Operating Temperature | 0 to 50°C |
Process Connection | 1/4" NPT |
Materials of Construction | Stainless steel |
Certifications | CE |
Details on capacities, pressure drop, and viscosity immunity ceilings. Refers to Table 1-1.
Describes the 4-20 mA HART transmitter with configurable alarms and pulse output for totalization.
Combines microprocessor sophistication with inductive alarm simplicity for advanced process control.
General recommendations for installing the flowmeter, including handling and orientation guidelines.
Procedures to follow before starting the flowmeter, ensuring proper installation and readiness for operation.
Guidance on initiating flow slowly, checking for leaks, and bringing the system up to operating pressure safely.
Details on operating the flowmeter with transmitter options, including pre-programmed parameters and recalibration.
Steps for operating the flowmeter with transmitter and inductive alarms, covering start-up and alarm configuration.
Instructions for operating the flowmeter with a transmitter and LCD display, including programming and access.
Procedures for operating with inductive alarms, including modifying set points and adjusting alarm positions.
Important safety warnings and precautions for servicing the meter and controller, including seal compatibility.