3.3 SAP Appendix Q Results
SAP 2005 (See SAP - PCDB for further details) http://www.ncm-pcdb.org.uk/sap/
SAP 2012 (See SAP - PCDB for further details) http://www.ncm-pcdb.org.uk/sap/
Exhaust Terminal
Configuration
Airflow Rate
(l/s)
100% Variable
Specific Fan
Power
(W/l/s)
Heat Exchange
Efficiency (%)
Energy Savings
Trust Best
Practice
Compliance
Kitchen + 1 Wet
Room
15 0.48 94 YES
Kitchen + 2 Wet
Room
21 0.42 93 YES
Kitchen + 3 Wet
Room
27 0.41 92 YES
Kitchen + 4 Wet
Room
33 0.45 91 YES
Kitchen + 5 Wet
Room
39 0.49 90 YES
Kitchen + 6 Wet
Room
45 0.56 90 YES
Kitchen + 7 Wet
Room
51 0.65 89 YES
Exhaust Terminal
Configuration
Airflow Rate
(l/s)
100% Variable
Specific Fan
Power
(W/l/s)
Heat Exchange
Efficiency (%)
Energy Savings
Trust Best
Practice
Compliance
Kitchen + 1 Wet
Room
21 0.45 93 YES
Kitchen + 2 Wet
Room
29 0.45 92 YES
Kitchen + 3 Wet
Room
37 0.49 91 YES
Kitchen + 4 Wet
Room
45 0.58 90 YES
Kitchen + 5 Wet
Room
53 0.67 88 YES
Kitchen + 6 Wet
Room
61 0.83 87 YES
Kitchen + 7 Wet
Room
69 0.99 86 YES