EasyManua.ls Logo

Brother b831 - Clearance between Needle and Rotary Hook

Brother b831
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
[D NEEDLE AND ROTARY HOOK TIMING
ADJUSTMENT
1.
Clearance
between
needle
and
rotary
hook
point
Needle
Rotarv
hook
point
Should
touch
lightly
Needle
guard
o
0.05~0.1
mm
1k
f 1
1P
r
0
sL
qI
(1) Loosen screws (a).® and
©,
and adjust the clearance between the needle and the rotary hook point to somewhere
between 0.05 and 0.1 mm by moving rotary hook O to right or left.
(2) After adjusting the
clearance
between
the
needle
and
the
rotary hookpoint, adjust
the
needle
guard
so
thatthe
needle
and
the
needle
guard
lightly
touch
each
other.
*
After
the adjustment, securely tighten screws ®, ® and ©.
The needle guard on the rotary hook is to prevent
the
needle from striking the rotary hook point.
* Be
sure
to readjust
the
rotary hook
needle
guard position
when
replacing
the
rotary hook.
2.
Needle
bar
rise
and
height
Rotary
hook
point
Needle
1.5
mm
(B837)
2.2
mm
(B838)
2.4
mm
(8837)
^
2.8
mm
(8838)
^
Needle
bar
rise
(1) Turn the feed adjusting knob to position 0.
(2)
Loosen
screws
O lor
lower
shaft
spiral
gearO- and
move
lower
shaft
spiral
gearO tothe
right
or
left
sothatthe
rotary
hookpoint
will
be at the center lineofthe needlewhen the needle rises 2.4 mmwith8837, 2.8 mmwith
BBSS
from
its
lowest
position.
* The rotary hook shaft has a screw seat, so the above adjustment cannot be made with the pinion gear.
*
When
tightening
screws
O
for
lower
shaft
spiral
gear O.
make
sure that it is in
line
with
the screw seat.
Needle
bar
height
(1) Turn the feed adjusting dial to position 0 (8837) or 4 (8838).
(2) Loosen screws
O.
and movethe needle bar up or down to adjust the clearance betweenthe top ofthe needle eye and
the rotary hook point to 1.5 mm (8837) or 2.2 mm (8838), when the rotary hookpointis in linewith the center of
the
needle.
*
After
the adjustment, tighten screw O securely.
Model
Application
Needle
bar
rise
Feed
control
dial
Standard
Thread
cutter
Standard
Thread
cutter
1
18-837
Thick
materials
2.4
mm
2.4
mm
0 0
1
18-838
Thick
materials
2.8
mm
0
^ ^
-61
-

Table of Contents