Effectivity: 916 i A / C24
Edition 0 / Rev. 1
BRP-Rotax Page 2-5
December 01 2023
NOTICE
Operating the engine below (90 to 110 °C / 194 to 230 °F) may
lead to formation of condensation water in the lubrication sys-
tem. To evaporate possibly accumulated condensation water,
at least once a day 100 °C (212 °F) oil temperature must be
reached.
Coolant
temperature
Parameter Min. Max.
Coolant temperature
at ground idle, start
procedure and warm
up
-20 °C (-4 °F)
Coolant temperature
at normal operation
(up to Critical
Altitude)
120 °C (248 °F)
Exhaust gas
temperature.
Parameter Min. Max.
Exhaust gas
temperature.
950 °C (1742 °F)
EGT-Split
EGT- Split is the difference between the actual highest EGT val-
ue of the actual lowest EGT value.
Parameter Min. Max.
EGT-Split at
> 3 Liter/hour (Fuel
consumption).
200 °C (392 °F)
EGT-Split at
< 3 Liter/hour (Fuel
consumption).
500 °C (932 °F)